Observational Study
. 2021 Apr;28(2):464-477.
doi: 10.1007/s12350-020-02515-4. Epub 2021 Mar 9.

Global and regional cardiac dysfunction quantified by 18F-FDG PET scans can predict ventricular arrhythmia in patients with implantable cardioverter defibrillator

Affiliations
Observational Study

Global and regional cardiac dysfunction quantified by 18F-FDG PET scans can predict ventricular arrhythmia in patients with implantable cardioverter defibrillator

Ran Jing et al. J Nucl Cardiol. 2021 Apr.

Abstract

Background: A low appropriate therapy rate indicates that a minority of patients will benefit from their implantable cardioverter defibrillator (ICD). Quantitative measurements from 18F-fluorodeoxyglucose positron emission tomography (18F-FDG PET) may predict ventricular arrhythmia (VA) occurrence after ICD placement.

Methods: We performed a prospective observational study and recruited patients who required ICD placement. Pre-procedure image scans were performed. Patients were followed up for VA occurrence. Associations between image results and VA were analyzed.

Results: In 51 patients (33 males, 53.9 ± 17.2 years) analyzed, 17 (33.3%) developed VA. Compared with patients without VA, patients with VA had significantly larger values in scar area (17.7 ± 12.4% vs. 7.0 ± 7.9%), phase standard deviation (51.4° ± 14.0° vs. 34.0° ± 15.0°), bandwidth (172.9° ± 39.8° vs. 128.7° ± 49.9°), sum thickening score (STS, 29.5 ± 11.1 vs. 17.8 ± 13.2), and sum motion score (42.9 ± 11.5 vs. 33.0 ± 19.0). Cox regression analysis and receiver operating characteristic curve analysis showed that scar size, dyssynchrony, and STS were associated with VA occurrence (HR, 4.956, 95% CI 1.70-14.46).

Conclusion: Larger left ventricular scar burden, increased dyssynchrony, and higher STS quantified by 18F-FDG PET may indicate a higher VA incidence after ICD placement.

Keywords: Left ventricular dyssynchrony; Myocardial metabolic imaging; Ventricular tachyarrhythmia; Wall thickening.

PubMed Disclaimer

Comment in

References

    1. Antiarrhythmics versus Implantable Defibrillators I. A comparison of antiarrhythmic-drug therapy with implantable defibrillators in patients resuscitated from near-fatal ventricular arrhythmias. N Engl J Med 1997;337:1576-83. - DOI
    1. Bokhari F, Newman D, Greene M, Korley V, Mangat I, Dorian P. Long-term comparison of the implantable cardioverter defibrillator versus amiodarone: Eleven-year follow-up of a subset of patients in the Canadian Implantable Defibrillator Study (CIDS). Circulation 2004;110:112-6. - DOI
    1. Singh JP, Hall WJ, McNitt S, Wang H, Daubert JP, Zareba W, et al. Factors influencing appropriate firing of the implanted defibrillator for ventricular tachycardia/fibrillation: Findings from the Multicenter Automatic Defibrillator Implantation Trial II (MADIT-II). J Am Coll Cardiol 2005;46:1712-20. - DOI
    1. Weeke P, Johansen JB, Jorgensen OD, Nielsen JC, Moller M, Videbaek R, et al. Mortality and appropriate and inappropriate therapy in patients with ischaemic heart disease and implanted cardioverter-defibrillators for primary prevention: Data from the Danish ICD Register. Europace 2013;15:1150-7. - DOI
    1. Al-Khatib SM, Stevenson WG, Ackerman MJ, Bryant WJ, Callans DJ, Curtis AB, et al. 2017 AHA/ACC/HRS Guideline for Management of Patients With Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death: Executive Summary: A report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society. J Am Coll Cardiol 2018;72:1677-749. - DOI

Publication types