. 2021 May;41(5):1729-1741.
doi: 10.1007/s10792-021-01732-1. Epub 2021 Mar 27.

Evaluation of topographic, tomographic, topometric, densitometric, and aberrometric features of cornea with pentacam HR system in subclinical keratoconus

Affiliations

Evaluation of topographic, tomographic, topometric, densitometric, and aberrometric features of cornea with pentacam HR system in subclinical keratoconus

Haci Hasan Ozkan et al. Int Ophthalmol. 2021 May.

Abstract

Purpose: To investigate topographic, tomographic, topometric, densitometric, and aberrometric parameters in subclinical keratoconus with the Pentacam HR imaging system.

Methods: Data of 3128 patients were evaluated, finding in 108 patients clinical keratoconus in one eye and subclinical keratoconus in the other. Corneal topographic, tomographic, topometric, densitometric, and aberrometric values obtained using the Pentacam HR imaging system were compared between clinical keratoconus, subclinical keratoconus, and normal eyes.

Results: Comparing eyes with subclinical keratoconus and the control group, while flat K, horizontal coma, horizontal trefoil, and vertical trefoil values were similar (p > 0.05 for each), all other parameters were significantly different (p < 0.05 for each). Densitometry values of eyes with subclinical keratoconus were significantly higher in all layers of the 0-2 mm annular area and in the anterior and central layers of the 2-6 mm annular area compared to the control group (p < 0.05 for each). According to the receiver operating characteristic curve analysis, the densitometry region with the largest area under the curve was the anterior layer of the 0-2 mm annular area. The sensitivity in this region was 79.4% and the specificity 73.2% in distinguishing eyes with subclinical keratoconus from normal eyes when 19.3 GSU was considered the threshold.

Conclusion: Corneal densitometry values in the 0-2 and 2-6 mm annular areas, especially in the anterior layers, are parameters that can be used to predict and distinguish subclinical keratoconus from normal eyes.

Keywords: Densitometry; Keratoconus; Subclinical keratoconus; Tomography; Topometry.

PubMed Disclaimer

References

    1. Romero-Jiménez M, Santodomingo-Rubido J, Wolffsohn JS (2010) Keratoconus: a review. Cont Lens Anter Eye 33:157–166
    1. Vazirani J, Basu S (2013) Keratoconus: current perspectives. Clin Ophthalmol 7:2019–2030 - PubMed - PMC
    1. Meek KM, Tuft SJ, Huang Y, Gil PSI, Hayes S, Newton RH, Bron AJ (2005) Changes in collagen orientation and distribution in keratoconus corneas. Invest Ophthalmol Vis Sci 46:1948–1956 - PubMed
    1. Li X, Rabinowitz YS, Rasheed K, Yang H (2004) Longitudinal study of the normal eyes in unilateral keratoconus patients. Ophthalmology 111:440–446 - PubMed
    1. Oruçoğlu F (2013) Incidence and tomographic evaluation of unilateral keratoconus. Turk J Ophthalmol 43:83–86

LinkOut - more resources