Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2022;40(1):78-84.
doi: 10.1159/000516177. Epub 2021 Mar 29.

Does ProCore Fine-Needle Biopsy Really Improve the Clinical Outcome of Endoscopic Ultrasound-Guided Sampling of Pancreatic Masses?

Affiliations

Does ProCore Fine-Needle Biopsy Really Improve the Clinical Outcome of Endoscopic Ultrasound-Guided Sampling of Pancreatic Masses?

Gabriele Delconte et al. Dig Dis. 2022.

Abstract

Introduction: Fine-needle biopsy (FNB) has been suggested to provide better histological samples as compared to endoscopic ultrasound fine-needle aspiration (EUS-FNA). However, studies comparing EUS-FNA and EUS-FNB for pancreatic lesions reported contrasting results. The aim of this study was to compare the clinical performance of EUS-FNA versus EUS-FNB with the ProCore needle for the investigation of pancreatic lesions.

Methods: We reviewed all patients undergoing EUS for the investigation of pancreatic lesions from August 2012 to September 2018. From August 2012 to January 2015, all procedures were performed with standard needles, whereas from February 2015 to September 2018, the use of ProCore needles had been introduced. Data on diagnostic accuracy, number of needle passes, and/or adverse events were collected.

Results: Three hundred twenty-four patients were retrospectively evaluated: 190 (58.6%) underwent EUS-FNA and 134 (41.4%) EUS-FNB. Both EUS-FNA and EUS-FNB showed high diagnostic accuracy for malignancy (94% [95% CI: 89-97%] vs. 94% [95% CI: 89-98%]). Notably, there were no differences between EUS-FNA and EUS-FNB in terms of sensitivity, specificity, positive and negative likelihood ratio, histological core tissue retrieval, adverse events, or number of needle passes. However, subgroup analysis noted a higher diagnostic accuracy for 25G EUS-FNB as compared to 25G EUS-FNA (85.7 vs. 55.5%; *p = 0.023).

Conclusion: EUS-FNB with the ProCore needle is safe and feasible in pancreatic lesions. The ProCore needle did not provide any advantage in terms of diagnostic accuracy, sensitivity, specificity, positive and/or negative likelihood ratio, or acquisition of the core specimen; therefore, its routine application is not supported.

Keywords: Endoscopic ultrasound; Histological core tissue; Immunohistochemistry; Pancreas; ProCore needles.

PubMed Disclaimer

Similar articles

Cited by

MeSH terms

LinkOut - more resources