. 2021;53(2):184-186.
doi: 10.5114/ait.2021.104098.

Precautions with right supraclavicular approach and oximetry central venous catheter

Affiliations

Precautions with right supraclavicular approach and oximetry central venous catheter

Tomohiro Yamamoto et al. Anaesthesiol Intensive Ther. 2021.
No abstract available

PubMed Disclaimer

Conflict of interest statement

none.

Figures

FIGURE 1
FIGURE 1
Postoperative chest X-ray showing Edwards PreSep Oximetry Catheter with the tip located exactly at the carina level. An 8.5 Fr Edwards PreSep Oximetry Catheter (∇) was inserted at a depth of 10 cm inside an adult patient with a height of 163 cm and weighing 42 kg, and its tip was located exactly at the carina level by the postoperative chest X-ray
FIGURE 2
FIGURE 2
The catheter tips of the 8.5 Fr Edwards PreSep Oximetry Catheter and a normal central venous catheter (CVC) (e.g. 12G SMAC Plus triple lumen CVC). The openings of the proximal lumen and medial lumen are located at approximately 7 cm and 5 cm, respectively, from the catheter tip in the 8.5 Fr Edwards PreSep Oximetry Catheter (A), farther away from the catheter tip than normal CVCs (B)

References

    1. Swan HJ, Ganz W, Forrester J, Marcus H, Diamond G, Chonette D. Catheterization of the heart in man with use of a flow-directed balloon-tipped catheter. N Engl J Med 1970; 283: 447-451. doi: 10.1056/NEJM197008272830902. - DOI - PubMed
    1. Ganz W, Donoso R, Marcus HS, Forrester JS, Swan HJ. A new technique for measurement of cardiac output by thermodilution in man. Am J Cardiol 1971; 27: 392-396. doi: 10.1016/0002-9149(71)90436-x. - DOI - PubMed
    1. Yu DT, Platt R, Lanken PN, et al. . Relationship of pulmonary artery catheter use to mortality and resource utilization in patients with severe sepsis. Crit Care Med 2003; 31: 2734-2741. doi: 10.1097/01.CCM.0000098028.68323.64. - DOI - PubMed
    1. Richard C, Warszawski J, Anguel N, et al. . Early use of the pulmonary artery catheter and outcomes in patients with shock and acute respiratory distress syndrome: a randomized controlled trial. JAMA 2003; 290: 2713-2720. doi: 10.1001/jama.290.20.2713. - DOI - PubMed
    1. Binanay C, Califf RM, Hasselblad V, et al. . Evaluation study of congestive heart failure and pulmonary artery catheterization effectiveness: the ESCAPE trial. JAMA 2005; 294: 1625-1633. doi: 10.1001/jama.294.13.1625. - DOI - PubMed

LinkOut - more resources