. 2021 May;413(13):3455-3469.
doi: 10.1007/s00216-021-03291-x. Epub 2021 Apr 2.

Smartphone-enabled field monitoring tool for rapid hexavalent chromium detection in water

Affiliations

Smartphone-enabled field monitoring tool for rapid hexavalent chromium detection in water

Sushant D Bamane et al. Anal Bioanal Chem. 2021 May.

Abstract

Chromium contamination of soil and water is a serious environmental and public health concern as the hexavalent form of chromium [Cr(VI)] is readily soluble in water and is a confirmed carcinogen. There is an imminent need for a robust, low-cost, and simple analytical technique to facilitate in situ monitoring of Cr(VI) in water. Current quantitative methods of Cr(VI) detection are largely laboratory-based, time-consuming, expensive, and require training for implementation. In this contribution, a portable, easy-to-use, and compact measuring tool is presented that provides Cr(VI) concentration within 10 min of water sampling over a linear range of 0-3 mg L-1. This tool utilizes a relatively inexpensive camera-enabled smartphone with a custom-made test chamber attachment to seamlessly perform Cr(VI) measurements on water samples in the field. For analysis, an android-based software application was developed that directs the user to perform a simple series of steps following the diphenylcarbazide-based colorimetric method prescribed by the American Public Health Association. The tool was validated against a standard UV-visible spectrophotometer for a variety of synthetic and naturally contaminated water samples, with correlation factors greater than 0.993 (p < .001). The colorimetric method was also validated against a non-colorimetric Cr(VI) detection technique-ion chromatography-inductively coupled plasma mass spectrometry. Furthermore, Cr(VI) detection limits for the smartphone-enabled colorimetric method were found to be within 1.3-11.6 μg L-1, which were significantly better than reported for commercially available field test kits, and even surpassed the limits exhibited by a typical spectrophotometer (25-50 μg L-1). Finally, real-time mapping of source waters at a contaminated site was demonstrated by remote logging of Cr(VI) water quality data and corresponding GPS coordinates into a cloud server. This study highlights the potential role of smartphone-based monitoring tool in providing information to the affected community and enabling safe access to drinking water. An accurate, robust, simple-to-use, and economic method to measure hexavalent chromium in water within 10 min of sampling at site.

Keywords: Cr(VI) detection in water; Optical sensors; Real-time mapping of contaminated zones; Smartphone-based test kit.

PubMed Disclaimer

References

    1. Mitra S, Sarkar A, Sen S. Removal of chromium from industrial effluents using nanotechnology: a review. Nanotechnol Environ Eng. 2017;2(1):11. - DOI
    1. Alloway BJ. Heavy metals in soils. 2nd ed. Glasgow, UK: Blackie Academic and Professional; 1995.
    1. Azeez JO, Adekunle IO, Atiku OO, Akande KB, Jamiu-Azeez SO. Effect of nine years of animal waste deposition on profile distribution of heavy metals in Abeokuta, south-western Nigeria and its implication for environmental quality. Waste Manag. 2009;29(9):2582–6. - PubMed - DOI
    1. Rai D, Zachara JM. Chemical attenuation rate coefficients and constants in leachate migration: final report February 1984: Volume 1. Electric Power Research Institute; 1984. Report No.: EPRI-EA-3356-Vol.1 ON: DE84009432.
    1. Salnikow K, Zhitkovich A. Genetic and epigenetic mechanisms in metal carcinogenesis and co-carcinogenesis: nickel, arsenic, and chromium. Chem Res Toxicol. 2007;21(1):28–44. - PubMed - PMC - DOI