Multicenter Study
. 2021 Jun:163:162-171.
doi: 10.1016/j.resuscitation.2021.03.028. Epub 2021 Apr 2.

SSEP amplitude accurately predicts both good and poor neurological outcome early after cardiac arrest; a post-hoc analysis of the ProNeCA multicentre study

Collaborators, Affiliations
Multicenter Study

SSEP amplitude accurately predicts both good and poor neurological outcome early after cardiac arrest; a post-hoc analysis of the ProNeCA multicentre study

Maenia Scarpino et al. Resuscitation. 2021 Jun.

Abstract

Aim: To assess if, in comatose resuscitated patients, the amplitude of the N20 wave (N20amp) of somatosensory evoked potentials (SSEP) can predict 6-months neurological outcome.

Setting: Multicentre study in 13 Italian intensive care units.

Methods: The N20amp in microvolts (μV) was measured at 12 h, 24 h, and 72 h from cardiac arrest, along with pupillary reflex (PLR) and a 30-min EEG classified according to the ACNS terminology. Sensitivity and false positive rate (FPR) of N20amp alone or in combination were calculated.

Results: 403 patients (age 69[58-68] years) were included. At 12 h, an N20amp >3 μV predicted good neurological outcome (Cerebral Performance Categories [CPC] 1-2) with 61[50-72]% sensitivity and 11[6-18]% FPR. Combining it with a benign (continuous or nearly continuous) EEG increased sensitivity to 91[82-96]%. For poor outcome (CPC 3-5), an N20Amp ≤0.38 μV, ≤0.73 μV and ≤1.01 μV at 12 h, 24 h, and 72 h, respectively, had 0% FPR with sensitivity ranging from 61[51-69]% and 82[76-88]%. Sensitivity was higher than that of a bilaterally absent N20 at all time points. At 12 h and 24 h, a highly malignant (suppression or burst-suppression) EEG and bilaterally absent PLR achieved 0% FPR only when combined with SSEP. A combination of all three predictors yielded a 0[0-4]% FPR, with maximum sensitivity of 44[36-53]%.

Conclusion: At 12 h from arrest, a high N20Amp predicts good outcome with high sensitivity, especially when combined with benign EEG. At 12 h and 24 h from arrest a low-voltage N20amp has a high sensitivity and is more specific than EEG or PLR for predicting poor outcome.

Keywords: Cardiac arrest; Coma; Electroencephalogram; Prognosis; Pupillary light reflex; Short-latency somatosensory evoked poitentials (SSEPs).