Application and Clinical Analysis of Remote Fetal Heart Rate Monitoring Platform in Continuous Fetal Heart Rate Monitoring Images
- PMID: 33824713
- PMCID: PMC8007337
- DOI: 10.1155/2021/5517692
Application and Clinical Analysis of Remote Fetal Heart Rate Monitoring Platform in Continuous Fetal Heart Rate Monitoring Images
Retraction in
-
Retracted: Application and Clinical Analysis of Remote Fetal Heart Rate Monitoring Platform in Continuous Fetal Heart Rate Monitoring Images.J Healthc Eng. 2023 Oct 11;2023:9826106. doi: 10.1155/2023/9826106. eCollection 2023. J Healthc Eng. 2023. PMID: 37860315 Free PMC article.
Abstract
Fetal heart sound is an important part of fetal monitoring and has attracted extensive research and attention from scholars at home and abroad in recent years. The fetal heart rate, extracted from the fetal heart sound signal, is one of the important indicators that reflect the health of the fetus in the womb. In this study, a maternal-fetal Holter monitor based on f ECG technology was used to collect maternal heart rate, fetal heart rate, and uterine contractions signals, isolate the fetal heart rate, and design an algorithm to extract the fetal heart rate baseline, acceleration, variation, wake-up cycle, and nonlinear parameters. Using statistical methods to analyze the average value and range of various characteristic parameters of fetal heart rate under continuous long-term monitoring, the results show that the baseline has a downward trend from 10 o'clock in the night to 4 o'clock in the morning and is the lowest around 2 o'clock in the morning. The area and acceleration time were significantly higher than those in the suspicious group. However, there was no significant difference in the number of acceleration values between the two groups; the proportion of small mutations in the normal group was lower than that of the suspicious group and the proportion of medium mutations was higher than that of the suspicious group. There is no statistically significant difference in maternal age, gestational age at childbirth, pregnancy comorbidities, and complication rates in the five-level interpretation system of ACOG (2009), RCOG (2007), SOGC (2007), and the United States (2007). The difference of pregnancy and parity in various images was statistically significant, P < 0.05. The second type of fetal heart rate monitoring images appeared in the highest among the diagnostic standards, and the difference in the second type of fetal heart rate monitoring images between the various diagnostic standards was statistically significant, P ≤ 0.001.
Copyright © 2021 Xuan Yang et al.
Conflict of interest statement
The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
Figures








Similar articles
-
Influence of gestational age and time of day in baseline and heart rate variation of fetuses.Technol Health Care. 2016 Apr 29;24 Suppl 2:S471-6. doi: 10.3233/THC-161170. Technol Health Care. 2016. PMID: 27163306
-
Effect of uterine contractions on fetal heart rate in pregnancy: a prospective observational study.Acta Obstet Gynecol Scand. 2016 Oct;95(10):1129-35. doi: 10.1111/aogs.12949. Acta Obstet Gynecol Scand. 2016. PMID: 27460848
-
Novel uterine contraction monitoring to enable remote, self-administered nonstress testing.Am J Obstet Gynecol. 2022 Apr;226(4):554.e1-554.e12. doi: 10.1016/j.ajog.2021.11.018. Epub 2021 Nov 8. Am J Obstet Gynecol. 2022. PMID: 34762863 Clinical Trial.
-
Use of continuous electronic fetal monitoring in a preterm fetus: clinical dilemmas and recommendations for practice.J Pregnancy. 2011;2011:848794. doi: 10.1155/2011/848794. Epub 2011 Sep 13. J Pregnancy. 2011. PMID: 21922045 Free PMC article. Review.
-
[Fetal monitoring during the active second stage of labor].J Gynecol Obstet Biol Reprod (Paris). 2008 Feb;37 Suppl 1:S93-100. doi: 10.1016/j.jgyn.2007.11.015. J Gynecol Obstet Biol Reprod (Paris). 2008. PMID: 18206318 Review. French.
Cited by
-
Accuracy of a Noninvasive, Wearable, Wireless, ECG-Based, Intrapartum Monitoring Tool Against the Conventional Ultrasound-Based CTG.J Obstet Gynaecol India. 2025 Apr;75(Suppl 1):340-347. doi: 10.1007/s13224-024-01998-2. Epub 2024 Aug 31. J Obstet Gynaecol India. 2025. PMID: 40390897
-
Study on the clinical value of the wearable foetal electrocardiogram monitoring system.Technol Health Care. 2024;32(6):4031-4040. doi: 10.3233/THC-231752. Technol Health Care. 2024. PMID: 39031401 Free PMC article.
-
Retracted: Application and Clinical Analysis of Remote Fetal Heart Rate Monitoring Platform in Continuous Fetal Heart Rate Monitoring Images.J Healthc Eng. 2023 Oct 11;2023:9826106. doi: 10.1155/2023/9826106. eCollection 2023. J Healthc Eng. 2023. PMID: 37860315 Free PMC article.
References
-
- Chaturvedi A., Kumar M. Consistent observing of fetal pulse and UteruswithDrawls. European Journal of Molecular & Clinical Medicine. 2020;7(4):145–150.
-
- Zhang X., Sun J., Li C. Development and research of exercise heart rate monitoring system under the concept of Internet of things telemedicine and mobile health. Journal of Medical Imaging and Health Informatics. 2021;11(4):1106–1111.
-
- Widadi S., Manzila Z. A., Ahmad I. Aroma electric therapy equipment with atmega8-based heart rate monitoring. Journal of Robotics and Control (JRC) 2020;1(2):49–54. doi: 10.18196/jrc.1211. - DOI
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources