Delayed or failure to follow-up abnormal breast cancer screening mammograms in primary care: a systematic review
- PMID: 33827476
- PMCID: PMC8028768
- DOI: 10.1186/s12885-021-08100-3
Delayed or failure to follow-up abnormal breast cancer screening mammograms in primary care: a systematic review
Abstract
Background: Successful breast cancer screening relies on timely follow-up of abnormal mammograms. Delayed or failure to follow-up abnormal mammograms undermines the potential benefits of screening and is associated with poorer outcomes. However, a comprehensive review of inadequate follow-up of abnormal mammograms in primary care has not previously been reported in the literature. This review could identify modifiable factors that influence follow-up, which if addressed, may lead to improved follow-up and patient outcomes.
Methods: A systematic literature review to determine the extent of inadequate follow-up of abnormal screening mammograms in primary care and identify factors impacting on follow-up was conducted. Relevant studies published between 1 January, 1990 and 29 October, 2020 were identified by searching MEDLINE®, Embase, CINAHL® and Cochrane Library, including reference and citation checking. Joanna Briggs Institute Critical Appraisal Checklists were used to assess the risk of bias of included studies according to study design.
Results: Eighteen publications reporting on 17 studies met inclusion criteria; 16 quantitative and two qualitative studies. All studies were conducted in the United States, except one study from the Netherlands. Failure to follow-up abnormal screening mammograms within 3 and at 6 months ranged from 7.2-33% and 27.3-71.6%, respectively. Women of ethnic minority and lower education attainment were more likely to have inadequate follow-up. Factors influencing follow-up included physician-patient miscommunication, information overload created by automated alerts, the absence of adequate retrieval systems to access patient's results and a lack of coordination of patient records. Logistical barriers to follow-up included inconvenient clinic hours and inconsistent primary care providers. Patient navigation and case management with increased patient education and counselling by physicians was demonstrated to improve follow-up.
Conclusions: Follow-up of abnormal mammograms in primary care is suboptimal. However, interventions addressing amendable factors that negatively impact on follow-up have the potential to improve follow-up, especially for populations of women at risk of inadequate follow-up.
Keywords: Abnormal mammogram; Breast cancer screening; Inadequate follow-up; Primary care.
Conflict of interest statement
The authors declare no conflict of interest.
Figures
References
-
- Myers ER, Moorman P, Gierisch JM, Havrilesky LJ, Grimm LJ, Ghate S, et al. Benefits and harms of breast Cancer screening: a systematic review. JAMA. 2015;314(15):1615–34. 10.1001/jama.2015.13183. - PubMed
-
- Kothari A, Fentiman IS. 22. Diagnostic delays in breast cancer and impact on survival. Int J Clin Pract. 2003;57(3):200–203. - PubMed
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous
