Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 1988 Jan;18(1):32-8.

[Comparison of permanent cardiac pacing and cardiac pacing on demand in mixed carotid sinus syndrome. Acute- and medium-term follow-up study]

[Article in Italian]
Affiliations
  • PMID: 3384245
Clinical Trial

[Comparison of permanent cardiac pacing and cardiac pacing on demand in mixed carotid sinus syndrome. Acute- and medium-term follow-up study]

[Article in Italian]
M Brignole et al. G Ital Cardiol. 1988 Jan.

Abstract

The aim of the study was to evaluate the importance of atrial synchronism for pacing therapy of patients with mixed carotid sinus syndrome. On 23 patients (21 m, 2 f; mean age 69 +/- 8 years) affected by symptomatic mixed carotid sinus syndrome we performed: 1) the study of ventriculo-atrial conduction, 2) the evaluation of pacemaker effect and 3) the carotid sinus massage in standing position during VVI and DVI temporary pacing. All patients received a permanent DVI pacemaker and then underwent a two-month period single-blind, randomized, cross-over study on DVI vs VVI mode. During DVI period, no syncope occurred in any patients, minor symptoms persisted in 11 (48%) of them; during VVI period syncopes recurred in 3 patients, symptoms requiring the withdrawal of VVI pacing and premature DVI reprogramming in 8, minor symptoms were observed in 17 (74%). A comparison between 14 patients who preferred DVI period (Group A) and the remaining 9 patients who had no preference for DVI and VVI period (Group B) revealed that Group A patients had a greater pacemaker effect (-34 +/- 16 mmHg vs -16 +/- 14 mmHg; p less than 0.02) and a higher prevalence of ventriculo-atrial conduction (78% vs 44%; p = 0.1), while the entity of the systolic pressure fall caused by carotid sinus massage was similar in the two groups both during VVI mode (Group A -51 +/- 16 mmHg vs Group B -56 +/- 27 mmHg) and DVI mode (Group A -38 +/- 17 mmHg vs Group B -45 +/- 17 mmHg).(ABSTRACT TRUNCATED AT 250 WORDS)

PubMed Disclaimer

LinkOut - more resources