Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2021 Sep;26(5):473-479.
doi: 10.1177/10742484211006998. Epub 2021 Apr 12.

Comparison of Outcomes of Enoxaparin Bridge Therapy in HeartMate II versus HeartWare HVAD Recipients

Affiliations
Comparative Study

Comparison of Outcomes of Enoxaparin Bridge Therapy in HeartMate II versus HeartWare HVAD Recipients

Mitulkumar Patel et al. J Cardiovasc Pharmacol Ther. 2021 Sep.

Abstract

Background: There is a lack of robust data evaluating outcomes of enoxaparin "bridge" therapy in left ventricular assist device (LVAD) patients.

Methods: We performed a retrospective study of HeartMate II (HM II) and HeartWare HVAD recipients that received therapeutic enoxaparin as "bridge" therapy to describe bleeding and thrombotic events and compare outcomes between devices. The primary endpoint was the incidence of bleeding within 30 days of "bridge" episode. Major bleeding was defined by INTERMACS criteria.

Results: We evaluated 257 "bridge" episodes in 54 patients, 35 with a HM II device and 19 with an HVAD device that underwent 176 and 81 bridging episodes, respectively. The median INR prior to "bridge" was lower in the HM II group compared to the HVAD group (1.5 vs 1.7, P < .01), however, there was no difference in the median duration of "bridge" therapy (7 vs 7 days, P = .42). There were a total of 30 (12%) bleeding episodes, with the majority in the HM II group vs HVAD (26 [15%] vs 4 [5%], P = .02). We observed 3 (1%) thromboembolic events in 2 (4%) patients with an HVAD device. On multivariate analysis, the presence of a HM II device was associated with a 4-fold increased risk of bleeding.

Conclusion: We found the use of enoxaparin "bridge" therapy to be associated with a higher incidence of bleeding in patients with a HM II device compared with an HVAD device. Assessment of device- and patient-specific factors should be evaluated to minimize bleeding events.

Keywords: LVAD; bleeding; enoxaparin; pharmacology; thrombosis.

PubMed Disclaimer

Publication types

LinkOut - more resources