The Correlation between Head of Bed Angle and Intra-Abdominal Pressure of Intubated Patients; a Pre-Post Clinical Trial
- PMID: 33870210
- PMCID: PMC8035694
- DOI: 10.22037/aaem.v9i1.1065
The Correlation between Head of Bed Angle and Intra-Abdominal Pressure of Intubated Patients; a Pre-Post Clinical Trial
Abstract
Introduction: The recommended position for measuring Intra-Abdominal Pressure (IAP) is the supine position. However, patients put in this position are prone to Ventilator-associated pneumonia. This study was done to evaluate the relationship between bed head angle and IAP measurements of intubated patients in the intensive care unit.
Methods: In this clinical trial, seventy-six critically ill patients under mechanical ventilation were enrolled. IAP measurement was performed every 8 hours for 24 hours using the KORN method in three different degrees of the head of bed (HOB) elevation (0 , 15 , and 30 ). Bland-Altman analysis was performed to identify the bias and limits of agreement among the three HOBs. According to World Society of the Abdominal Compartment Syndrome (WSACS), we can consider two IAP techniques equivalent if a bias of <1 mmHg and limits of agreement of - 4 to +4 were found between them. Data were analyzed using SPSS statistical software (v. 19), and the significance level was considered as 0.05.
Results: The prevalence of intra-abdominal hypertension was 18.42%. Mean ± standard deviation (SD) of IAP were 8.44 ± 4.02 mmHg for HOB angle 0°, 9.58 ± 4.52 for HOB angle 15 and 11.10 ± 4.73 for HOB angle 30o (p = 0.0001). The IAP measurement bias between HOB angle 0°and HOB angle 15° was 1.13 mmHg. This bias was 2.66 mmHg between HOB angle 0° and HOB angle 30°.
Conclusion: Elevation of HOB angle from 0 to 30 degree significantly increases IAP. It seems that the measurement of IAP at HOB angle 15° was more reliable than 30°.
Keywords: Compartment syndrome; Critical care; Head of Bed; Intra-abdominal Hypertension; Pressure; Supine Position.
Figures
References
-
- McBeth PB, Zygun DA, Widder S, Cheatham M, Zengerink I, Glowa J, et al. Effect of patient positioning on intra-abdominal pressure monitoring. The American journal of surgery. 2007;193(5):644–7. - PubMed
-
- Cheatham ML, De Waele JJ, De Laet I, De Keulenaer B, Widder S, Kirkpatrick AW, et al. The impact of body position on intra-abdominal pressure measurement: a multicenter analysis. Critical care medicine. 2009;37(7):2187–90. - PubMed
-
- Roberts DJ, Ball CG, Kirkpatrick AW. Increased pressure within the abdominal compartment: intra-abdominal hypertension and the abdominal compartment syndrome. Current opinion in critical care. 2016;22(2):174–85. - PubMed
-
- Kirkpatrick AW, Roberts DJ, De Waele J, Jaeschke R, Malbrain ML, De Keulenaer B, et al. Intra-abdominal hypertension and the abdominal compartment syndrome: updated consensus definitions and clinical practice guidelines from the World Society of the Abdominal Compartment Syndrome. Intensive care medicine. 2013;39(7):1190–206. - PMC - PubMed
-
- Malbrain M, Chiumello D, Cesana B, Reintam Blaser A, Starkopf J, Sugrue M, et al. A systematic review and individual patient data meta-analysis on intra-abdominal hypertension in critically ill patients: the wake-up project. World initiative on Abdominal Hypertension Epidemiology, a Unifying Project (WAKE-Up!). Minerva Anestesiol. 2014;80(3):293–306. - PubMed
LinkOut - more resources