Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2022 Feb;31(2):136-146.
doi: 10.1111/jopr.13369. Epub 2021 May 4.

Failure Load of Monolithic Lithium Disilicate Implant-Supported Single Crowns Bonded to Ti-base Abutments versus to Customized Ceramic Abutments after Fatigue

Affiliations

Failure Load of Monolithic Lithium Disilicate Implant-Supported Single Crowns Bonded to Ti-base Abutments versus to Customized Ceramic Abutments after Fatigue

F A Spitznagel et al. J Prosthodont. 2022 Feb.

Abstract

Purpose: This laboratory study analyzed the influence of retention mode (screw- vs cement retained) and fatigue application on the failure load of monolithic lithium-disilicate (LDS) implant-supported single crowns (ISSC).

Material and methods: A total of 72 samples of monolithic LDS (*Ivoclar Vivadent) ISSC were divided into three groups (n = 24) according to their type of retention mode: Group Ti-CAD: Titanium base (SICvantage CAD/CAM Abutment red (SIC invent AG), screw-retained milled monolithic LDS (IPS e.max CAD*); Group Ti-P: Titanium base (SICvantage CAD/CAM Abutment red), screw-retained pressed monolithic LDS (IPS e.max Press*) and Group Ti-Cust: Titanium base with cemented press LDS (IPS e.max Press*) crown on a LDS (IPS e.max Press*) custom abutment. A mandibular first molar implant-supported single crown model was investigated (Titanium implant: SICvantage-max, SIC invent AG, diameter: 4.2 mm, length: 11.5 mm). Half of each group (n = 12) w​ere exposed to fatigue with cyclic mechanical loading (F = 198 N, 1.2 million cycles) and simultaneous thermocycling (5-55°C). Single load to failure testing was performed, before (Subgroups Ti-CAD, Ti-P, and Ti-Cust) and after (Subgroups Ti-CAD-F, Ti-P-F, and Ti-Cust-F) fatigue. Weibull distribution was used to determine the characteristic strength and Weibull modulus differences between groups. Probability of survival at 900N load was calculated.

Results: No samples failed during fatigue. Characteristic strength values were as follow: Ti-CAD: 3259.5N, Ti-CAD-F: 2926N, Ti-P: 2763N, Ti-P-F: 2841N, Ti-Cust: 2789N, Ti-Cust-F: 2194N. Whereas no difference was observed between pressed or milled monolithic crowns cemented to Ti-base, regardless of loading condition, fatigue decreased the characteristic strength of crowns cemented to custom abutments. Probability of survival at 900 N was not significantly different between groups.

Conclusions: Screw-retained pressed or milled monolithic LDS ISSC, cemented directly to Ti-base abutments or LDS crowns cemented to custom ceramic abutments resist physiological chewing forces after simulated 5-year aging in the artificial mouth and presented equally high probability of survival. However, a significant decrease in load to failure was observed in LDS crowns cemented to custom ceramic abutments after fatigue. Prospective clinical trials are needed to confirm the results of this laboratory investigation.

Keywords: Ceramics; dental implants; fracture; implant supported dental prosthesis; lifetime; monolithic crowns; titanium bases.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Edelhoff D, Schweiger J, Prandtner O, et al. Metal-free implant-supported single-tooth restorations. Part I: abutments and cemented crowns. Quintessence Int 2019;50:176-184
    1. Edelhoff D, Schweiger J, Prandtner O, et al. Metal-free implant-supported single-tooth restorations. Part II: hybrid abutment crowns and material selection. Quintessence Int 2019;50:260-269
    1. Sailer I, Sailer T, Stawarczyk B, et al. In vitro study of the influence of the type of connection on the fracture load of zirconia abutments with internal and external implant-abutment connections. Int J Oral Maxillofac implants 2009;24:850-858
    1. Sailer I, Asgeirsson AG, Thoma DS, et al. Fracture strength of zirconia implant abutments on narrow diameter implants with internal and external implant abutment connections: a study on the titanium resin base concept. Clin Oral Implants Res 2018;29:411-423
    1. Pitta J, Hicklin SP, Fehmer V, et al. Mechanical stability of zirconia meso-abutments bonded to titanium bases restored with different monolithic all-ceramic crowns. Int J Oral Maxillofac Implants 2019;34:1091-1097

LinkOut - more resources