Abstract
The spectrum of complications in the use of intraocular lenses (IOL) is different today from at the time of their introduction. Opacities in the IOL material are increasingly described in the literature as a reason for IOL explantation. This paper provides an overview of the different forms of IOL material opacities. Currently relevant forms of IOL material opacities and their effects on optical quality are summarized. The main reason for opacification in hydrophilic IOLs is calcification, whereas in hydrophobic IOLs it is mainly the formation of so-called glistenings that is reported. Most material opacities affect various optical parameters and lead to increased intraocular straylight. In case of a disturbing material opacification, the only therapeutic option is to replace the opacified IOL.
Das Spektrum an Komplikationen und die Explantationsgründe bei der Verwendung von Intraokularlinsen (IOL) haben sich durch die Weiterentwicklung der Kataraktchirurgie verändert. Eintrübungen des Materials beeinflussen dabei unterschiedlich stark die optische Qualität. Im Fall einer störenden Eintrübung des Materials ist auch heute noch – trotz aller Fortschritte auf dem Gebiet der IOL-Materialien – ein Austausch der IOL die einzige Behandlungsoption.
Thieme. All rights reserved.
Conflict of interest statement
Similar articles
-
[Opacification of intraocular lenses: laboratory and clinical findings].Ophthalmologe. 2021 Jul;118(7):633-642. doi: 10.1007/s00347-020-01259-3. Epub 2020 Nov 13. Ophthalmologe. 2021. PMID: 33188443 Free PMC article. Review. German.
-
Reasons for explantation, demographics, and material analysis of 200 intraocular lens explants.J Cataract Refract Surg. 2020 Jan;46(1):20-26. doi: 10.1016/j.jcrs.2019.08.045. J Cataract Refract Surg. 2020. PMID: 32050228
-
A Novel Approach for Assessing Visual Impairment Caused by Intraocular Lens Opacification: High-Resolution Optical Coherence Tomography.Am J Ophthalmol. 2021 Jun;226:108-116. doi: 10.1016/j.ajo.2021.02.001. Epub 2021 Feb 8. Am J Ophthalmol. 2021. PMID: 33571474
-
Opacification of Hydrophilic Acrylic Intraocular Lenses: Overview of Laboratory Methods for Histological Analysis and Replication of IOL Calcification.Klin Monbl Augenheilkd. 2023 Aug;240(8):960-970. doi: 10.1055/a-2073-8526. Epub 2023 Jun 30. Klin Monbl Augenheilkd. 2023. PMID: 37391183 English, German.
-
Akreos Adapt AO Intraocular lens opacification after vitrectomy in a diabetic patient: a case report and review of the literature.BMC Ophthalmol. 2016 Jun 8;16:82. doi: 10.1186/s12886-016-0268-3. BMC Ophthalmol. 2016. PMID: 27277708 Free PMC article. Review.
Cited by
-
[Hydrophobic surface properties of hydrophilic acrylic lenses do not protect against calcification].Ophthalmologie. 2023 Oct;120(10):1022-1028. doi: 10.1007/s00347-023-01862-0. Epub 2023 May 12. Ophthalmologie. 2023. PMID: 37171476 German.
-
Comparative analysis of in vitro accelerated glistening formation in foldable hydrophobic intraocular lenses.Int Ophthalmol. 2021 Sep;41(9):3073-3080. doi: 10.1007/s10792-021-01870-6. Epub 2021 May 19. Int Ophthalmol. 2021. PMID: 34013467 Free PMC article.
-
[Material properties of intraocular lenses: are there patient-relevant differences?].Ophthalmologe. 2021 Oct;118(10):1066-1067. doi: 10.1007/s00347-021-01490-6. Epub 2021 Sep 3. Ophthalmologe. 2021. PMID: 34477904 German. No abstract available.
-
[Liquefied after-cataract].Ophthalmologie. 2025 Jan;122(1):1. doi: 10.1007/s00347-024-02077-7. Epub 2024 Jul 4. Ophthalmologie. 2025. PMID: 38965072 German. No abstract available.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical