Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2022 Mar;41(3):585-595.
doi: 10.1002/jum.15732. Epub 2021 Apr 24.

Optic Nerve Sheath Diameter Ultrasound for Raised Intracranial Pressure: A Literature Review and Meta-analysis of its Diagnostic Accuracy

Affiliations
Meta-Analysis

Optic Nerve Sheath Diameter Ultrasound for Raised Intracranial Pressure: A Literature Review and Meta-analysis of its Diagnostic Accuracy

Waleed Aletreby et al. J Ultrasound Med. 2022 Mar.

Abstract

Optic nerve sheath diameter (ONSD) ultrasound is becoming increasingly more popular for estimating raised intracranial pressure (ICP). We performed a systematic review and analysis of the diagnostic accuracy of ONSD when compared to the standard invasive ICP measurement.

Method: We performed a systematic search of PUBMED and EMBASE for studies including adult patients with suspected elevated ICP and comparing sonographic ONSD measurement to a standard invasive method. Quality of studies was assessed using the QUADAS-2 tool by two independent authors. We used a bivariate model of random effects to summarize pooled sensitivity, specificity, and diagnostic odds ratio (DOR). Heterogeneity was investigated by meta-regression and sub-group analyses.

Results: We included 18 prospective studies (16 studies including 619 patients for primary outcome). Only one study was of low quality, and there was no apparent publication bias. Pooled sensitivity was 0.9 [95% confidence intervals (CI): 0.85-0.94], specificity was 0.85 (95% CI: 0.8-0.89), and DOR was 46.7 (95% CI: 26.2-83.2) with partial evidence of heterogeneity. The Area-Under-the-Curve of the summary Receiver-Operator-Curve was 0.93 (95% CI: 0.91-0.95, P < .05). No covariates were significant in the meta-regression. Subgroup analysis of severe traumatic brain injury and parenchymal ICP found no heterogeneity. ICP and ONSD had a correlation coefficient of 0.7 (95% CI: 0.63-0.76, P < .05).

Conclusion: ONSD is a useful adjunct in ICP evaluation but is currently not a replacement for invasive methods where they are feasible.

Keywords: intracranial pressure; meta-analysis; optic nerve sheath diameter; ultrasound.

PubMed Disclaimer

References

    1. Koziarz A, Sne N, Kegel F, et al. Optic nerve sheath diameter sonography for the diagnosis of increased intracranial pressure: a systematic review and meta-analysis protocol. BMJ Open 2017; 7:e016194. https://doi.org/10.1136/bmjopen-2017-016194.
    1. Robba C, Santori G, Czosnyka M, et al. Optic nerve sheath diameter measured sonographically as non-invasive estimator of intracranial pressure: a systematic review and meta-analysis. Intensive Care Med 2018; 44:1284-1294. https://doi.org/10.1007/s00134-018-5305-7.
    1. Fernando SM, Tran A, Cheng W, et al. Diagnosis of elevated intracranial pressure in critically ill adults: systematic review and meta-analysis. BMJ 2019; 366:l4225. https://doi.org/10.1136/bmj.l4225.
    1. Moretti R, Pizzi B. Ultrasonography of the optic nerve in neurocritically ill patients. Acta Anaesthesiol Scand 2011; 55:644-652. https://doi.org/10.1111/j.1399-6576.2011.02432.x.
    1. Dubourg J, Javouhey E, Geeraerts T, Messerer M, Kassai B. Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysis. Intensive Care Med 2011; 37:1059-1068. https://doi.org/10.1007/s00134-011-2224-2.

LinkOut - more resources