Volatile anesthetic gas concentration sensing using flow sensor fusion for use in Austere settings
- PMID: 33914229
- DOI: 10.1007/s10877-021-00700-5
Volatile anesthetic gas concentration sensing using flow sensor fusion for use in Austere settings
Abstract
Flow sensors are often sensitive to the presence of volatile anesthetics. However, this sensitivity provides a unique opportunity to combine flow sensors of differing technological principles as an alternative to measuring volatile anesthetic gas concentration, particularly for austere settings. To determine the feasibility of flow sensor fusion for volatile anesthetic concentrations monitoring, eight flow sensors were tested with isoflurane, sevoflurane, and desflurane, ranging in concentrations from 0-4.5%, 0-3.5%, and 0-18%, respectively. Pairs of flow sensors were fit to the volatile anesthetic gas concentration with a leave-one-out cross-validation method to reduce the likelihood of overfitting. Bland-Altman was used for the final evaluation of sensor pair performance. Several sensor pairs yielded limits of agreement comparable to the rated accuracy of a commercial infrared spectrometer. The ultrasonic and orifice-plate flowmeters yielded the most combinations of viable sensor pairs for all three volatile anesthetic gases. Conclusion: Measuring volatile anesthetic gases using flow sensor fusion is a feasible low-cost, low-maintenance alternative to infrared spectroscopy. In this study, testing was done under steady-state conditions in 100% oxygen. Further testing is necessary to ensure sensor fusion performance under conditions that are more reflective of the clinical use case.
Keywords: Flow sensor; Inhalational anesthetics; Sensor fusion; Volatile anesthetic monitoring.
© 2021. The Author(s), under exclusive licence to Springer Nature B.V.
References
-
- Kotob F, Twersky RS. Anesthesia outside the operating room : general overview and monitoring standards. Int Anesthesiol Clin. 2003;41(2):1–15. - DOI
-
- Gatrad AR, Gatrad S, Gatrad A. Equipment donation to developing countries. Anaesthesia. 2007;62(s1):90–5. https://doi.org/10.1111/j.1365-2044.2007.05309.x . - DOI - PubMed
-
- “Guidelines For Health Care Equipment Donations,” World Heath Organization, no. March, 2000.
-
- Beringer RM, Eltringham RJ. The Glostavent: evolution of an anaesthetic machine for developing countries. Anaesth Intensive Care. 2008;36(3):442–8. - DOI
-
- Dubowitz G, et al. Accuracy of the Lifebox pulse oximeter during hypoxia in healthy volunteers. Anaesthesia. 2013;68(12):1220–3. https://doi.org/10.1111/anae.12382 . - DOI - PubMed
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources