The current status of CZT SPECT myocardial blood flow and reserve assessment: Tips and tricks
- PMID: 33939162
- DOI: 10.1007/s12350-021-02620-y
The current status of CZT SPECT myocardial blood flow and reserve assessment: Tips and tricks
Abstract
Cardiac PET-derived measurements of myocardial blood flow (MBF) and myocardial flow reserve (MFR) are proven robust indexes of the severity of coronary artery disease (CAD). They facilitate the diagnosis of diffuse epicardial and microvascular disease and are also of prognostic significance. However, low availability and high cost have limited their wide clinical implementation. Over the last 15 years, cadmium zinc telluride (CZT)-based detectors have been implemented into SPECT imaging devices. Myocardial perfusion scintigraphy can be performed faster and with less radiation exposure as compared with standard gamma cameras. Rapid dynamic SPECT studies with higher count rates can be performed. This technological breakthrough has renewed the interest in SPECT MBF assessment in patients with CAD. Currently, two cardiac-centered CZT gamma cameras are available commercially-Discovery NM530c and D-SPECT. They differ in parameters such as collimator design, number of detectors, sensitivity, spatial resolution and image reconstruction. A number of publications have focused on the feasibility of dynamic CZT SPECT and on the correlation with cardiac PET and invasive coronary angiography measurements of fractional flow reserve. Current study reviews the present status of MBF and MFR assessment with CZT SPECT. It also aims to provide an overview of specific issues related to acquisition, processing and interpretation of quantitative studies in patients with CAD.
Keywords: CAD; CZT; Myocardial blood flow; Myocardial flow reserve; Myocardial ischemia; SPECT.
© 2021. American Society of Nuclear Cardiology.
Comment in
-
Myocardial blood flow quantitation with the SPECT technique: Is it ready to be a substitute for PET myocardial blood flow quantitation?J Nucl Cardiol. 2022 Dec;29(6):3152-3154. doi: 10.1007/s12350-021-02697-5. Epub 2021 Jun 27. J Nucl Cardiol. 2022. PMID: 34180028 No abstract available.
Similar articles
-
Comparison between N13NH3-PET and 99mTc-Tetrofosmin-CZT SPECT in the evaluation of absolute myocardial blood flow and flow reserve.J Nucl Cardiol. 2021 Oct;28(5):1906-1918. doi: 10.1007/s12350-019-01939-x. Epub 2019 Nov 14. J Nucl Cardiol. 2021. PMID: 31728817
-
Myocardial blood flow evaluation with dynamic cadmium-zinc-telluride single-photon emission computed tomography: Bright and dark sides.Diagn Interv Imaging. 2023 Jul-Aug;104(7-8):323-329. doi: 10.1016/j.diii.2023.02.001. Epub 2023 Feb 14. Diagn Interv Imaging. 2023. PMID: 36797156 Review.
-
Quantification of myocardial flow reserve using a gamma camera with solid-state cadmium-zinc-telluride detectors: Relation to angiographic coronary artery disease.J Nucl Cardiol. 2021 Jun;28(3):876-884. doi: 10.1007/s12350-019-01775-z. Epub 2019 Jun 20. J Nucl Cardiol. 2021. PMID: 31222529
-
Clinical usefulness of quantification of myocardial blood flow and flow reserve using CZT-SPECT for detecting coronary artery disease in patients with normal stress perfusion imaging.J Cardiol. 2020 Apr;75(4):400-409. doi: 10.1016/j.jjcc.2019.09.006. Epub 2019 Nov 18. J Cardiol. 2020. PMID: 31753710
-
Advances in Single-Photon Emission Computed Tomography: Hardware, Software, and Myocardial Flow Reserve.Cardiol Clin. 2023 May;41(2):117-127. doi: 10.1016/j.ccl.2023.01.001. Epub 2023 Feb 25. Cardiol Clin. 2023. PMID: 37003670 Review.
Cited by
-
Chinese expert consensus on the diagnosis and treatment of coronary microvascular diseases (2023 Edition).MedComm (2020). 2023 Dec 19;4(6):e438. doi: 10.1002/mco2.438. eCollection 2023 Dec. MedComm (2020). 2023. PMID: 38116064 Free PMC article. Review.
-
2023 Guidelines of the Taiwan Society of Cardiology on the Diagnosis and Management of Chronic Coronary Syndrome.Acta Cardiol Sin. 2023 Jan;39(1):4-96. doi: 10.6515/ACS.202301_39(1).20221103A. Acta Cardiol Sin. 2023. PMID: 36685161 Free PMC article.
-
A Comparison of Dynamic SPECT Coronary Flow Reserve with TIMI Frame Count in the Treatment of Non-Obstructive Epicardial Coronary Patients.Clin Interv Aging. 2023 Nov 2;18:1831-1839. doi: 10.2147/CIA.S429450. eCollection 2023. Clin Interv Aging. 2023. PMID: 37937265 Free PMC article.
-
Comparison of global and regional myocardial blood flow quantification using dynamic solid-state detector SPECT and Tc-99 m-sestamibi or Tc-99 m-tetrofosmin in a routine clinical setting.Int J Cardiovasc Imaging. 2025 Mar;41(3):537-548. doi: 10.1007/s10554-025-03339-4. Epub 2025 Jan 30. Int J Cardiovasc Imaging. 2025. PMID: 39885112 Free PMC article.
-
Accuracy of a whole-body single-photon emission computed tomography with a thallium-bromide detector: Verification via Monte Carlo simulations.Med Phys. 2025 Jun;52(6):4079-4095. doi: 10.1002/mp.17724. Epub 2025 Feb 27. Med Phys. 2025. PMID: 40017160 Free PMC article.
References
-
- Driessen RS, Raijmakers PG, Stuijfzand WJ, Knaapen P. Myocardial perfusion imaging with PET. Int J Cardiovasc Imaging 2017;33:1021-31. https://doi.org/10.1007/s10554-017-1084-4 . - DOI
-
- Gullberg GT, Di Bella EV, Sinusas AJ. Estimation of coronary flow reserve: Can SPECT compete with other modalities? J Nucl Cardiol 2001;8:620-5. https://doi.org/10.1067/mnc.2001.118121 . - DOI
-
- Iida H, Eberl S, Kim K, Tamura Y, Ono Y, Nakazawa M, et al. Absolute quantitation of myocardial blood flow with 201Tl and dynamic SPECT in canine: Optimisation and validation of kinetic modelling. Eur J Nucl Med Mol Imaging 2008;35:896-905. https://doi.org/10.1007/s00259-007-0654-4 . - DOI
-
- Hsu B, Hu LH, Yang BH, Chen LC, Chen YK, Ting CH, et al. SPECT myocardial blood flow quantitation toward clinical use: A comparative study with (13)N-Ammonia PET myocardial blood flow quantitation. Eur J Nucl Med Mol Imaging 2017;44:117-28. https://doi.org/10.1007/s00259-016-3491-5 . - DOI
-
- Sugihara H, Yonekura Y, Kataoka K, Fukai D, Kitamura N, Taniguchi Y. Estimation of coronary flow reserve with the use of dynamic planar and SPECT images of Tc-99m tetrofosmin. J Nucl Cardiol 2001;8:575-9. https://doi.org/10.1067/mnc.2001.115934 . - DOI
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous