Review
. 2021 Nov;34(6):406-415.
doi: 10.1111/sdi.12977. Epub 2021 May 3.

Vascular access, membranes and circuit for CRRT

Affiliations
Review

Vascular access, membranes and circuit for CRRT

Luis A Juncos et al. Semin Dial. 2021 Nov.

Abstract

The advances in the technology for providing continuous renal replacement therapy (CRRT) have led to an increase in its utilization throughout the world. However, circuit life continues to be a major problem. It leads not only to decreased delivery of dialysis but also causes blood loss, waste of disposables, alters dose delivery of medications and nutrition, and increases nurse workload, all of which increases healthcare cost. Premature circuit failure can be caused by numerous factors that can be difficult to dissect out. The first component is the vascular access; without a well-placed, functioning access, delivery of CRRT becomes very difficult. This is usually accomplished by placing a short-term dialysis catheter into either the right internal jugular or femoral vein. The tips should be located at the caval atrial junction or inferior vena cava. In addition to establishing suitable vascular access, a comprehensive understanding of the circuit facilitates the development of a methodical approach in providing efficient CRRT characterized by optimal circuit life. Moreover, it aids in determining the cause of circuit failure in patients experiencing recurrent episodes. This review therefore summarizes the essential points that guide providers in establishing optimal vascular access. We then provide an overview of the main components of the CRRT circuit including the blood and fluid pumps, the hemofilter, and pressure sensors, which will assist in identifying the key mechanisms contributing to premature failure of the CRRT circuit.

PubMed Disclaimer

References

REFERENCES

    1. Venkataraman R, Kellum JA, Palevsky P. Dosing patterns for continuous renal replacement therapy at a large academic medical center in the United States. J Crit Care. 2002;17(4):246-250.
    1. Vesconi S, Cruz DN, Fumagalli R, et al. Delivered dose of renal replacement therapy and mortality in critically ill patients with acute kidney injury. Crit Care. 2009;13(2):R57.
    1. Claure-Del Granado R, Macedo E, Chertow GM, et al. Effluent volume in continuous renal replacement therapy overestimates the delivered dose of dialysis. Clin J Am Soc Nephrol. 2011;6(3):467-475.
    1. Rewa OG, Tolwani A, Mottes T, et al. Quality of care and safety measures of acute renal replacement therapy: workgroup statements from the 22nd acute disease quality initiative (ADQI) consensus conference. J Crit Care. 2019;54:52-57.
    1. Kashani K, Rosner MH, Haase M, et al. Quality improvement goals for acute kidney injury. Clin J Am Soc Nephrol. 2019;14(6):941.

LinkOut - more resources