Test-retest reliability of tone- and 40 Hz train-evoked gamma oscillations in female rats and their sensitivity to low-dose NMDA channel blockade
- PMID: 33944972
- DOI: 10.1007/s00213-021-05856-1
Test-retest reliability of tone- and 40 Hz train-evoked gamma oscillations in female rats and their sensitivity to low-dose NMDA channel blockade
Abstract
Rationale: Schizophrenia patients consistently show deficits in sensory-evoked broadband gamma oscillations and click-evoked entrainment at 40 Hz, called the 40-Hz auditory steady-state response (ASSR). Since such evoked oscillations depend on cortical N-methyl D-aspartic acid (NMDA)-mediated network activity, they can serve as pharmacodynamic biomarkers in the preclinical and clinical development of drug candidates engaging these circuits. However, there are few test-retest reliability data in preclinical species, a prerequisite for within-subject testing paradigms.
Objective: We investigated the long-term psychometric stability of these measures in a rodent model.
Methods: Female rats with chronic epidural implants were used to record tone- and 40 Hz click-evoked responses at multiple time points and across six sessions, spread over 3 weeks. We assessed reliability using intraclass correlation coefficients (ICC). Separately, we used mixed-effects ANOVA to examine time and session effects. Individual subject variability was determined using the coefficient of variation (CV). Lastly, to illustrate the importance of long-term measure stability for within-subject testing design, we used low to moderate doses of an NMDA antagonist MK801 (0.025-0.15 mg/kg) to disrupt the evoked response.
Results: We found that 40-Hz ASSR showed good reliability (ICC=0.60-0.75), while the reliability of tone-evoked gamma ranged from poor to good (0.33-0.67). We noted time but no session effects. Subjects showed a lower variance for ASSR over tone-evoked gamma. Both measures were dose-dependently attenuated by NMDA antagonism.
Conclusion: Overall, while both evoked gamma measures use NMDA transmission, 40-Hz ASSR showed superior psychometric properties of higher ICC and lower CV, relative to tone-evoked gamma.
Keywords: ASSR; Auditory steady-state response; EEG; Gamma oscillations; NMDA; Pharmacodynamic biomarker; Test-retest reliability.
© 2021. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.
References
-
- Brenner, CA, Krishnan, GP, Vohs, JL, Ahn, WY, Hetrick, WP, Morzorati, SL, O’Donnell, BF (2009). Steady state responses: electrophysiological assessment of sensory function in schizophrenia. In Schizophrenia Bulletin (Vol. 35, Issue 6, pp. 1065–1077). Oxford Academic. https://doi.org/10.1093/schbul/sbp091
-
- Buzsáki G, Wang X-J (2012) Mechanisms of gamma oscillations. Annu Rev Neurosci 35(1):203–225. https://doi.org/10.1146/annurev-neuro-062111-150444 - DOI - PubMed - PMC
-
- Cardin JA, Carlén M, Meletis K, Knoblich U, Zhang F, Deisseroth K, Tsai LH, Moore CI (2009) Driving fast-spiking cells induces gamma rhythm and controls sensory responses. Nature 459(7247):663–667. https://doi.org/10.1038/nature08002 - DOI - PubMed - PMC
-
- Cervenka MC, Franaszczuk PJ, Crone NE, Hong B, Caffo BS, Bhatt P, Lenz FA, Boatman-Reich D (2013) Reliability of early cortical auditory gamma-band responses. Clin Neurophysiol 124(1):70–82. https://doi.org/10.1016/j.clinph.2012.06.003 - DOI - PubMed
-
- Cleophas TJM, De Vogel EM (1998) Crossover studies are a better format for comparing equivalent treatments than parallel-group studies. Pharm World Sci 20(3):113–117. https://doi.org/10.1023/A:1008626002664 - DOI - PubMed