. 2021 Apr 1:36:107027.
doi: 10.1016/j.dib.2021.107027. eCollection 2021 Jun.

Spontaneous long-term and urethane induced hippocampal EEG power, activity and temperature data from mice lacking the Cav3.2 voltage-gated Ca2+ channel

Affiliations

Spontaneous long-term and urethane induced hippocampal EEG power, activity and temperature data from mice lacking the Cav3.2 voltage-gated Ca2+ channel

Anna Papazoglou et al. Data Brief. .

Abstract

This article provides raw relative electroencephalographic (EEG) power, temperature and activity data from controls and Cav3.2 deficient mice. Radiotransmitter implantation was carried out in male experimental mice under ketamine/xylazine narcosis. Following a recovery period, radiotelemetric EEG recordings from the hippocampal CA1 region were obtained under spontaneous 24 h long-term conditions and post urethane injection. Relative EEG power values (%) for 2 s epochs were analysed for the following frequency ranges: delta 1 ( δ 1 , 0.5-4 Hz), delta 2 ( δ 2 , 1-4 Hz), theta 1 ( θ 1 , 4-8 Hz), theta 2 ( θ 2 , 4-12 Hz), alpha ( α , 8-12 Hz), sigma ( σ , 12-16 Hz), beta 1 ( β 1 , 12-30 Hz), beta 2 ( β 2 , 16-24 Hz), beta 3 ( β 3 , 16-30 Hz), gamma low ( γ l o w , 30-50 Hz), gamma mid ( γ m i d , 50-70 Hz), gamma high ( γ h i g h , 70-100 Hz), gamma ripples ( γ r i p p l e s , 80-200 Hz), and gamma fast ripples ( γ f a s t r i p p l e s , 200-500 Hz). In addition, subcutaneous temperature and relative activity data were analysed for both the light and dark cycle of two long-term recordings. The same type of data was obtained post urethane injection. Detailed information is provided for the age and body weight of the experimental animals, the technical specifications of the radiofrequency transmitter, the stereotaxic coordinates for the intracerebral, deep and epidural, surface EEG electrodes, the electrode features, the filtering and sampling characteristics, the analysed EEG frequency bands and the data acquisition parameters. EEG power data, temperature and activity data are available at MENDELEY DATA (doi:10.17632/x53km5sby6.1, URL: http://dx.doi.org/10.17632/x53km5sby6.1). Raw EEG data are available at zenodo (https://zenodo.org/).

Keywords: Activity; CA1; EEG; Hippocampus; Mouse; Power; Telemetry; Urethane.

PubMed Disclaimer

Conflict of interest statement

The authors declare that they have no known competing financial interests or personal relationships which have or could be perceived to have influenced the work reported in this article.

Similar articles

Cited by

References

    1. Arshaad M.I., Siwek M.E., Henseler C., Daubner J., Ehninger D., Hescheler J., Sachinidis A., Broich K., Papazoglou A., Weiergraber M. Enhanced hippocampal type II theta activity AND altered theta architecture in mice lacking the Cav3.2 T-type voltage-gated calcium channel. Sci. Rep. 2021;11:1099. doi: 10.1038/s41598-020-79763-4. - DOI - PMC - PubMed
    1. Lundt A., Wormuth C., Siwek M.E., Muller R., Ehninger D., Henseler C., Broich K., Papazoglou A., Weiergraber M. EEG radiotelemetry in small laboratory rodents: a powerful state-of-the art approach in neuropsychiatric, neurodegenerative, and epilepsy research. Neural Plast. 2016 doi: 10.1155/2016/8213878. 2016. - DOI - PMC - PubMed
    1. Papazoglou A., Lundt A., Wormuth C., Ehninger D., Henseler C., Soos J., Broich K., Weiergraber M. Non-restraining EEG radiotelemetry: epidural and deep intracerebral stereotaxic EEG electrode placement. J. Vis. Exp. 2016 doi: 10.3791/54216. - DOI - PMC - PubMed
    1. Weiergraber M., Henry M., Hescheler J., Smyth N., Schneider T. Electrocorticographic and deep intracerebral EEG recording in mice using a telemetry system. Brain Res. Protoc. 2005;14:154–164. doi: 10.1016/j.brainresprot.2004.12.006. - DOI - PubMed
    1. Muller R., Papazoglou A., Soos J., Lundt A., Wormuth C., Henseler C., Ehninger D., Broich K., Weiergraber M. Automatic detection of highly organized theta oscillations in the murine EEG. J. Vis. Exp. 2017 doi: 10.3791/55089. - DOI - PMC - PubMed

LinkOut - more resources