Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1988 Jun;53(6):971-88.
doi: 10.1016/S0006-3495(88)83178-3.

Simultaneous recording of calcium transients in skeletal muscle using high- and low-affinity calcium indicators

Affiliations
Comparative Study

Simultaneous recording of calcium transients in skeletal muscle using high- and low-affinity calcium indicators

M G Klein et al. Biophys J. 1988 Jun.

Abstract

To monitor cytosolic [Ca2+] over a wide range of concentrations in functioning skeletal muscle cells, we have used simultaneously the rapid but relatively low affinity calcium indicator antipyrylazo III (AP III) and the slower but higher affinity indicator fura-2 in single frog twitch fibers cut at both ends and voltage clamped with a double vaseline gap system. When both dyes were added to the end pool solution the cytosolic fura-2 concentration reached a steady level equal to the end pool concentration within approximately 2.5 h, a time when the AP III concentration was still increasing. For depolarizing pulses of increasing amplitude, the fura-2 fluorescence signal approached saturation when the simultaneously recorded AP III absorbance change was far from saturation. Comparison of simultaneously recorded fura-2 and AP III signals indicated that the mean values of the on and off rate constants for calcium binding to fura-2 in 18 muscle fibers were 1.49 x 10(8) M-1 s-1 and 11.9 s-1, respectively (mean KD = 89 nM), if all AP III in the fiber is assumed to behave as in calibrating solution and to be in instantaneous equilibrium with [Ca2+]. [Ca2+] transients calculated from the fura-2 signals using these rate constants were consistent with the [Ca2+] transients calculated from the AP III signals. Resting [Ca2+] or small changes in [Ca2+] which could not be reliably monitored with AP III could be monitored with fura-2 with little or no interference from changes in [Mg2+] or from intrinsic signals. The fura-2 signal was also less sensitive to movement artifacts than the AP III signal. After a [Ca2+] transient the fura-2 signal demonstrated a relatively small elevation of [Ca2+] that was maintained for many seconds.