Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 May 7;16(5):e0251236.
doi: 10.1371/journal.pone.0251236. eCollection 2021.

Diagnostic accuracy of point-of-care ultrasound for pulmonary tuberculosis: A systematic review

Affiliations

Diagnostic accuracy of point-of-care ultrasound for pulmonary tuberculosis: A systematic review

Jacob Bigio et al. PLoS One. .

Abstract

The advent of affordable, portable ultrasound devices has led to increasing interest in the use of point-of-care ultrasound (POCUS) for the detection of pulmonary TB (PTB). We undertook a systematic review of the diagnostic accuracy of POCUS for PTB. Five databases were searched for articles published between January 2010 and June 2020. Risk of bias was assessed using QUADAS-2. Data on sensitivity and specificity of individual lung ultrasound findings were collected, with variable reference standards including PCR and sputum smear microscopy. Six of 3,919 reviewed articles were included: five in adults and one in children, with a total sample size of 564. Studies had high risk of bias in many domains. In adults, subpleural nodule and lung consolidation were the lung ultrasound findings with the highest sensitivities, ranging from 72.5% to 100.0% and 46.7% to 80.4%, respectively. Only one study reported specificity data. Variability in sensitivity may be due to variable reference standards or may imply operator dependence. There is insufficient evidence to judge the diagnostic accuracy of POCUS for PTB. There is also no consensus on the optimal protocols for acquiring and analysing POCUS images for PTB. New studies which minimise potential sources of bias are required to further assess the diagnostic accuracy of POCUS for PTB.

PubMed Disclaimer

Conflict of interest statement

The authors have declared that no competing interests exist.

Figures

Fig 1
Fig 1. PRISMA study flowchart.
Fig 2
Fig 2. Forest plot showing sensitivity of different lung ultrasound findings in adults.

Similar articles

Cited by

References

    1. World Health Organization. Global tuberculosis report 2020. 2020.
    1. World Health Organization. The End TB Strategy. 2013.
    1. Naidoo P, Theron G, Rangaka MX, Chihota VN, Vaughan L, Brey ZO, et al.. The South African Tuberculosis Care Cascade: Estimated Losses and Methodological Challenges. J Infect Dis. 2017;216(suppl_7):S702–S13. 10.1093/infdis/jix335 . - DOI - PMC - PubMed
    1. Subbaraman R, Nathavitharana RR, Satyanarayana S, Pai M, Thomas BE, Chadha VK, et al.. The Tuberculosis Cascade of Care in India’s Public Sector: A Systematic Review and Meta-analysis. PLOS Medicine. 2016;13(10):e1002149. 10.1371/journal.pmed.1002149 - DOI - PMC - PubMed
    1. World Health Organization. Chest radiography in tuberculosis detection–summary of current WHO recommendations and guidance on programmatic approaches. 2016.

Publication types

LinkOut - more resources