. 1988;57(5):526-30.
doi: 10.1007/BF00418457.

A new dynamometer measuring concentric and eccentric muscle strength in accelerated, decelerated, or isokinetic movements. Validity and reproducibility

Affiliations

A new dynamometer measuring concentric and eccentric muscle strength in accelerated, decelerated, or isokinetic movements. Validity and reproducibility

J Y Seger et al. Eur J Appl Physiol Occup Physiol. 1988.

Abstract

A new computerized dynamometer (the SPARK System) is described. The system can measure concentric and eccentric muscle strength (torque) during linear or nonlinear acceleration or deceleration, isokinetic movements up to 400 degrees.s-1, and isometric torque. Studies were performed to assess: I. validity and reproducibility of torque measurements; II. control of lever arm position; III. control of different velocity patterns; IV. control of velocity during subject testing; and, V. intra-individual reproducibility. No significant difference was found between torque values computed by the system and known torque values (p greater than 0.05). No difference was present between programmed and external measurement of the lever arm position. Accelerating, decelerating and isokinetic velocity patterns were highly reproducible, with differences in elapsed time among 10 trials being never greater than 0.001 s. Velocity during concentric and eccentric isokinetic quadriceps contractions at 30 degrees.s-1, 120 degrees.s-1 and 270 degrees.s-1 never varied by more than 3 degrees.s-1 among subjects (N = 21). Over three days of testing, the overall error for concentric and eccentric quadriceps contraction peak torque values for 5 angular velocities between 30 degrees.s-1 and 270 degrees.s-1 ranged from 5.8% to 9.0% and 5.8% to 9.6% respectively (N = 25). The results indicate that the SPARK System provides valid and reproducible torque measurements and strict control of velocity. In addition, the intra-individual error is in accordance with those reported for other similar devices.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Acta Physiol Scand. 1983 Nov;119(3):317-20 - PubMed
    1. Med Sci Sports Exerc. 1986 Feb;18(1):44-9 - PubMed
    1. Acta Physiol Scand Suppl. 1976;443:1-45 - PubMed
    1. Exerc Sport Sci Rev. 1984;12:81-121 - PubMed
    1. Exerc Sport Sci Rev. 1986;14:1-44 - PubMed

Publication types