The prognostic value of transesophageal echocardiography after transvenous lead extraction: landscape after battle
- PMID: 33968618
- PMCID: PMC8102270
- DOI: 10.21037/cdt-20-871
The prognostic value of transesophageal echocardiography after transvenous lead extraction: landscape after battle
Abstract
Background: In patients undergoing transvenous lead extraction (TLE) transesophageal echocardiography (TEE) provide valuable information after procedure.
Methods: We analyzed data from 936 TEE performed in patients undergoing TLE between 2015 and 2019 (mean follow-up 566.23±224.47 days) and assessed the role of echocardiographic phenomena after procedure.
Results: Increment in tricuspid regurgitation (TR) was observed in 9% of patients after TLE. Factors increasing the risk of TR were: binding sites between lead and right ventricle (RV) (OR: 5.429), tricuspid valve (TV) (OR: 3.42), superior vena cava (SVC) (OR: 3.30) and lead-to-lead adhesions (OR: 2.88). Predisposing factors of residual structures after TLE were: asymptomatic masses on the leads (AMEL) (OR: 1.68), binding sites between SVC and cardiac structures (OR: 1.72), and multiple leads (OR: 1.30). Probability of vegetation remnants increased in the presence of abandoned leads (OR: 7.91). The risk factors of tamponade were: dwell time of the oldest lead (OR: 1.17), lead-to-lead adhesion (OR: 22.47), binding sites between lead and TV (OR: 6.08), RA (OR: 11.50), SVC (OR: 4.47), higher LVEF (OR: 2.35; P=0.006), female gender (OR: 5.43), multiple leads (OR: 2.11), looped leads (OR: 4.90) and AMEL (OR: 6.42). The risk of lead fracture was increased by: lead-to-lead adhesion (OR: 5.69), fibrosis binding the lead to RV (OR: 5.16), RA (OR: 2.39) and dwell time of the oldest lead (OR: 1.068). The mortality rate was 11.97% during follow-up. The risk of death was increased by: severe TR and vegetation remnants.
Conclusions: The most important phenomena evaluated after TLE are: tricuspid valve function, residual fibrosis and vegetation remnants, progression of pericardial effusion and retained lead fragments. Postoperative TEE provides information about the results of TLE and helps establish further management.
Keywords: Transvenous lead extraction (TLE); connective tissue scar; lead extraction-related tricuspid valve damage; retained lead fragments; transesophageal echocardiography (TEE); vegetation remnants.
2021 Cardiovascular Diagnosis and Therapy. All rights reserved.
Conflict of interest statement
Conflicts of Interest: All authors have completed the ICMJE uniform disclosure form (available at http://dx.doi.org/10.21037/cdt-20-871). The authors have no conflicts of interest to declare.
Figures
References
-
- Bongiorni MG, Burri H, Deharo JC, et al. 2018 EHRA expert consensus statement on lead extraction: recommendations on definitions, endpoints, research trial design, and data collection requirements for clinical scientific studies and registries: endorsed by APHRS/HRS/LAHRS. Europace 2018;20:1217-9. 10.1093/europace/euy050 - DOI - PubMed
-
- Wilkoff BL, Love CJ, Byrd CL, et al. Transvenous lead extraction: Heart Rhythm Society expert consensus on facilities, training, indications, and patient management: this document was endorsed by the American Heart Association (AHA). Heart Rhythm 2009;6:1085-104. 10.1016/j.hrthm.2009.05.020 - DOI - PubMed
LinkOut - more resources
Full Text Sources
Other Literature Sources