Variability in venous gas emboli following the same dive at 3,658 meters
- PMID: 33975402
- DOI: 10.22462/03.04.2021.2
Variability in venous gas emboli following the same dive at 3,658 meters
Retracted and republished in
-
Variability in venous gas emboli following the same dive at 3,658 meters.Undersea Hyperb Med. 2021 Fourth Quarter;48(4):469-476. Undersea Hyperb Med. 2021. PMID: 34847312
Abstract
Exposure to a reduction in ambient pressure such as in high-altitude climbing, flying in aircrafts, and decompression from underwater diving results in circulating vascular gas bubbles (i.e., venous gas emboli [VGE]). Incidence and severity of VGE, in part, can objectively quantify decompression stress and risk of decompression sickness (DCS) which is typically mitigated by adherence to decompression schedules. However, dives conducted at altitude challenge recommendations for decompression schedules which are limited to exposures of 10,000 feet in the U.S. Navy Diving Manual (Rev. 7). Therefore, in an ancillary analysis within a larger study, we assessed the evolution of VGE for two hours post-dive using echocardiography following simulated altitude dives at 12,000 feet. Ten divers completed two dives to 66 fsw (equivalent to 110 fsw at sea level by the Cross correction method) for 30 minutes in a hyperbaric chamber. All dives were completed following a 60-minute exposure at 12,000 feet. Following the dive, the chamber was decompressed back to altitude for two hours. Echocardiograph measurements were performed every 20 minutes post-dive. Bubbles were counted and graded using the Germonpré and Eftedal and Brubakk method, respectively. No diver presented with symptoms of DCS following the dive or two hours post-dive at altitude. Despite inter- and intra-diver variability of VGE grade following the dives, the majority (11/20 dives) presented a peak VGE Grade 0, three VGE Grade 1, one VGE Grade 2, four VGE Grade 3, and one VGE Grade 4. Using the Cross correction method for a 66-fsw dive at 12,000 feet of altitude resulted in a relatively low decompression stress and no cases of DCS.
Keywords: altitude; decompression illness; decompression stress; intravascular gas bubbles.
Copyright© Undersea and Hyperbaric Medical Society.
Conflict of interest statement
The authors of this paper declare no conflicts of interest exist with this submission.
Similar articles
-
Variability in venous gas emboli following the same dive at 3,658 meters.Undersea Hyperb Med. 2021 Fourth Quarter;48(4):469-476. Undersea Hyperb Med. 2021. PMID: 34847312
-
Hyperbaric Physics.2024 Jan 31. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2025 Jan–. 2024 Jan 31. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2025 Jan–. PMID: 28846268 Free Books & Documents.
-
Variability in circulating gas emboli after a same scuba diving exposure.Eur J Appl Physiol. 2018 Jun;118(6):1255-1264. doi: 10.1007/s00421-018-3854-7. Epub 2018 Apr 3. Eur J Appl Physiol. 2018. PMID: 29616324
-
The need for optimisation of post-dive ultrasound monitoring to properly evaluate the evolution of venous gas emboli.Diving Hyperb Med. 2011 Sep;41(3):139-46. Diving Hyperb Med. 2011. PMID: 21948499 Review.
-
Pathophysiology of inner ear decompression sickness: potential role of the persistent foramen ovale.Diving Hyperb Med. 2015 Jun;45(2):105-10. Diving Hyperb Med. 2015. PMID: 26165533 Review.
Cited by
-
Pulmonary Oxygen Toxicity Through Exhaled Breath Markers After Hyperbaric Oxygen Treatment Table 6.Front Physiol. 2022 May 10;13:899568. doi: 10.3389/fphys.2022.899568. eCollection 2022. Front Physiol. 2022. PMID: 35620607 Free PMC article.