Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2021 May 12;22(1):433.
doi: 10.1186/s12891-021-04312-7.

Volar locking plate versus external fixation for unstable distal radius fractures: a systematic review and meta-analysis based on randomized controlled trials

Affiliations
Meta-Analysis

Volar locking plate versus external fixation for unstable distal radius fractures: a systematic review and meta-analysis based on randomized controlled trials

Qi Gou et al. BMC Musculoskelet Disord. .

Abstract

Background: The outcomes for volar locking plate (VLP) and external fixation (EF) in distal radius fracture cases remain controversial. The current study of randomized controlled trials (RCTs) aimed to assess VLP and EF, which might benefit distal radius fracture cases.

Methods: RCTs comparing VLP and EF in distal radius fracture cases, until 18 March 2020, were systematically reviewed and summarized. The functional and radiographic outcomes, together with complications, for distal radius fracture cases, were evaluated.

Results: In total, 12 studies comprising 1205 distal radius fracture cases were included. The VLP group had observed lower disability in the arm shoulder and hand score (DASH) at 3rd, 6th, and 12th -month post-operation, with the mean differences (MDs) of - 10.43 (95 % CI = - 15.77 to - 5.08, P < 0.01), - 3.48 (95 % CI = - 6.37 to - 0.59, P = 0.02), and - 4.13 (95 % CI = - 6.94 to - 1.33, P < 0.01), respectively. The VLP group also had lower visual analog scale scores (VAS) compared to the EF group, with MDs of - 0.10 (95 % CI = - 0.18 to - 0.03, P < 0.01) for the former at 6th -month post-operation. Also, the EF group exhibited better grip strength than that in the VLP group, with MD of 12.48 (95 % CI = 7.00-17.95, P < 0.01) at the 3rd month and 4.54 (95 % CI = 0.31-8.76, P = 0.04) at 6th month. No significant differences in radiographic outcomes were observed between the VLP and EF groups (P > 0.05). The VLP group had a lower complication rate than that in the EF group.

Conclusions: VLP had a lower DASH score and VAS score but with lower grip strength. No significant differences in radiographic outcomes were observed. VLP had a lower complication rate than that of EF.

Keywords: Distal radius fractures; External fixation; Meta-analysis; Putcome; RCTs; Volar locking plates.

PubMed Disclaimer

Conflict of interest statement

The authors declare that they have no competing interests.

Figures

Fig. 1
Fig. 1
Flow chart of the study selection process
Fig. 2
Fig. 2
Risk of bias assessment of the included studies
Fig. 3
Fig. 3
Summarized disabilities of the arm shoulder and hand score
Fig. 4
Fig. 4
Summarized visual analog scale scores
Fig. 5
Fig. 5
Summarized grip strength results
Fig. 6
Fig. 6
Summarized wrist range of motion results after 3 months
Fig. 7
Fig. 7
Summarized wrist range of motion results after 6 months
Fig. 8
Fig. 8
Summarized wrist range of motion results after 12 months
Fig. 9
Fig. 9
Summarized radiological measurement results
Fig. 10
Fig. 10
Summarized complications

References

    1. Singer BR, McLauchlan GJ, Robinson CM, Christie J. Epidemiology of fractures in 15,000 adults: the influence of age and gender. J Bone Joint Surg Br. 1998;80(2):243–248. doi: 10.1302/0301-620X.80B2.0800243. - DOI - PubMed
    1. Paksima N, Panchal A, Posner MA, Green SM, Mehiman CT, Hiebert R. A meta-analysis of the literature on distal radius fractures: review of 615 articles. Bull Hosp Jt Dis. 2004;62(1–2):40–46. - PubMed
    1. Kawaguchi S, Sawada K, Nabeta Y, Hayakawa M, Aoki M. Recurrent dorsal angulation of the distal radius fracture during dynamic external fixation. J Hand Surg Am. 1998;23(5):920–925. doi: 10.1016/S0363-5023(98)80174-3. - DOI - PubMed
    1. Wolf JC, Weil WM, Hanel DP, Trumble TE. A biomechanic comparison of an internal radiocarpal-spanning 2.4-mm locking plate and external fixation in a model of distal radius fractures. J Hand Surg Am. 2006;31(10):1578–1586. doi: 10.1016/j.jhsa.2006.09.014. - DOI - PubMed
    1. Orbay JL, Fernandez DL. Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report. J Hand Surg Am. 2002;27(2):205–215. doi: 10.1053/jhsu.2002.32081. - DOI - PubMed