Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 May 15;188(6):187.
doi: 10.1007/s00604-021-04834-w.

Zeolite-iron oxide nanocomposite from fly ash formed a 'clubbell' structure: integration of cardiac biocapture macromolecules in serum on microelectrodes

Affiliations

Zeolite-iron oxide nanocomposite from fly ash formed a 'clubbell' structure: integration of cardiac biocapture macromolecules in serum on microelectrodes

Zhiqiang Liu et al. Mikrochim Acta. .

Abstract

A new zeolite-iron oxide nanocomposite (ZEO-IO) was extracted from waste fly ash of a thermal power plant and utilized for capturing aptamers used to quantify the myocardial infarction (MI) biomarker N-terminal prohormone B-type natriuretic peptide (NT-ProBNP); this was used in a probe with an integrated microelectrode sensor. High-resolution microscopy revealed that ZEO-IO displayed a clubbell structure and a particle size range of 100-200 nm. Energy-dispersive X-ray spectroscopy and X-ray photoelectron spectroscopy confirmed the presence of Si, Al, Fe, and O in the synthesized ZEO-IO. The limit of detection for NT-ProBNP was 1-2 pg/mL (0.1-0.2 pM) when the aptamer was sandwiched with antibody and showed the doubled current response even at a low NT-ProBNP abundance. A dose-dependent interaction was identified for this sandwich with a linear plot in the concentration range 1 to 32 pg/mL (0.1-3.2 pM) with a determination coefficient R2 = 0.9884; y = 0.8425x-0.5771. Without sandwich, the detection limit was 2-4 pg/mL (0.2-0.4 pM) and the determination coefficient was R2 = 0.9854; y = 1.0996x-1.4729. Stability and nonfouling assays in the presence of bovine serum albumin, cardiac troponin I, and myoglobin revealed that the aptamer-modified surface is stable and specific for NT-Pro-BNP. Moreover, NT-ProBNP-spiked human serum exhibited selective detection. This new nanocomposite-modified surface helps in detecting NT-Pro-BNP and diagnosing MI at stages of low expression.

Keywords: Aptasensor; Biomarker; Interdigitated electrode; Myocardial infarction; Zeolite.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Jo H, Gu H, Jeon W, Youn H, Her J, Kim SK, Lee J, Shin JH, Ban C (2015) Electrochemical aptasensor of cardiac troponin i for the early diagnosis of acute myocardial infarction. Anal Chem 87:9869–9875. https://doi.org/10.1021/acs.analchem.5b02312 - DOI - PubMed
    1. Sinha A, Gopinathan P, Da Chung Y et al (2019) Simultaneous detection of multiple NT-proBNP clinical samples utilizing an aptamer-based sandwich assay on an integrated microfluidic system. Lab Chip 19:1676–1685. https://doi.org/10.1039/c9lc00115h - DOI - PubMed
    1. Luchner A, Hengstenberg C, Löwel H et al (2002) N-terminal pro-brain natriuretic peptide after myocardial infarction a marker of cardio-renal function. Hypertension 39:99–104. https://doi.org/10.1161/hy0102.100537 - DOI - PubMed
    1. Zhou W, Jimmy Huang PJ, Ding J, Liu J (2014) Aptamer-based biosensors for biomedical diagnostics. Analyst 139(11):2627–2640 - DOI
    1. Lakshmipriya T, Fujimaki M, Gopinath SCB, Awazu K, Horiguchi Y, Nagasaki Y (2013) A high-performance waveguide-mode biosensor for detection of factor IX using PEG-based blocking agents to suppress non-specific binding and improve sensitivity. Analyst 138:2863–2870. https://doi.org/10.1039/c3an00298e - DOI - PubMed

MeSH terms

LinkOut - more resources