Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Aug;14(8):e202100094.
doi: 10.1002/jbio.202100094. Epub 2021 May 24.

Ex-vivo fluorescence confocal microscopy with digital staining for characterizing basal cell carcinoma on frozen sections: A comparison with histology

Affiliations

Ex-vivo fluorescence confocal microscopy with digital staining for characterizing basal cell carcinoma on frozen sections: A comparison with histology

Cristel Ruini et al. J Biophotonics. 2021 Aug.

Abstract

Ex-vivo fluorescence confocal microscopy (FCM) has been used on fresh tissue, but there is little experience on frozen sections. We evaluated the applicability of FCM on frozen sections of basal cell carcinomas (BCCs), stained with acridine orange and digitally colored to simulate hematoxylin and eosin (H&E) dyes. We compared our diagnostic accuracy in detecting and subtyping BCCs with FCM to our gold standard (H&E stained frozen sections used in 3D horizontal micrographic surgery). Fourty-six primary BCCs were analyzed for free margins as well as histological subtype with all FCM modes and conventional H&E staining. Adnexa, artifacts and diagnostic confidence were evaluated. Free margins were identified with a sensitivity and specificity of 92% and 91%. Concordance for tumor subtype was 88%. FCM may be used on both fresh tissue and frozen samples, although with reduced performance and different artifacts. The device is useful for the intraoperative diagnosis, subtyping and margin-mapping of BCCs.

Keywords: basal cell carcinoma; bedside histology; digital staining; ex-vivo confocal microscopy; micrographic surgery.

PubMed Disclaimer

Similar articles

Cited by

References

REFERENCES

    1. F. E. Mohs, Arch. Surg. 1941, 42, 279.
    1. J. Paoli, O. Cogrel, S. V. D. Geer, G. Krekels, J. D. Leeuw, Matthias, Moehrle, J. U. Ostertag, L. R. Buceta, N. Sheth, S. Läuchli in ESMS position document on the use of mohs micrographic surgery and other micrographic surgery techniques in Europe, 2019.
    1. L. F. Kopke, B. Konz, Hautarzt 1995, 46, 607.
    1. J. Perez-Anker, J. Malvehy, D. Moreno-Ramirez, Actas Dermosifiliogr 2020, 111, 236.
    1. D. Hartmann, S. Krammer, M. R. Bachmann, L. Mathemeier, T. Ruzicka, I. S. Bagci, T. von Braunmuhl, J. Biophotonics 2018, 11, e201700318.

Publication types

LinkOut - more resources