. 2021 May 15;188(6):190.
doi: 10.1007/s00604-021-04839-5.

Lithium cobalt phosphate electrode for the simultaneous determination of ascorbic acid, dopamine, and serum uric acid by differential pulse voltammetry

Affiliations

Lithium cobalt phosphate electrode for the simultaneous determination of ascorbic acid, dopamine, and serum uric acid by differential pulse voltammetry

Yanxue Xu et al. Mikrochim Acta. .

Abstract

Lithium cobalt phosphate (LCP) was prepared and modified on the surface of glassy carbon electrode (GCE) to fabricate the electrochemical sensor (LCP/GCE) for the simultaneous determination of ascorbic acid (AA), dopamine (DA), and serum uric acid (UA). The homogenous incorporation of carbon improved the conductivity of LCP. Benefiting from the small particle size distribution, LCP/GCE has a large active surface and responds to AA, DA, and UA sensitively and rapidly. For the simultaneous detection with differential pulse voltammetry the anodic peaks of AA, DA, and UA were well-separated and appeared at ~0 V, ~0.19 V, and ~ 0.33 V (vs. Ag/AgCl), respectively. The linear responses toward AA, DA, and UA were in the range 10 μM-8.0 mM, 10 nM-10 μM, and 0.020 μM-25 μM; the detection limits were estimated to be 8.10 μM, 7.50 nM, and 22.7 nM (S/N = 3), respectively. The excellent selectivity and reproducibility of LCP/GCE enable serum UA to be detected without the interference of AA and DA. The recoveries of DA and AA in the serum sample were in the range 95 to 111%. The results indicate that LCP has the potential to be developed as the sensing devices to be applied to in vitro diagnosis. The lithium-ion battery cathodic material, LCP with the excellent adsorption and catalytic behavior, was utilized to fabricate the electrochemical sensor for the sensitive and simultaneous detection of AA, DA, and UA, which achieved the low detection limits and the wide concentration ranges. LCP/GCE can be used for the quantitative detection of serum UA without the interference of DA and AA. In addition, the recoveries of DA and AA in human serum were satisfactory, which illustrate the reliability of LCP/GCE to be applied to in vitro diagnosis.

Keywords: Dopamine; Electrochemical sensor; Lithium cobalt phosphate; Serum uric acid.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Sajid M, Nazal MK, Mansha M, Alsharaa A, Jillani SMS, Basheer C (2016) Chemically modified electrodes for electrochemical detection of dopamine in the presence of uric acid and ascorbic acid: a review. TrAC Trends Anal Chem 76:15–29 - DOI
    1. Zhao J, Wang S, Lu S, Bao X, Sun J, Yang X (2018) An enzyme cascade-triggered fluorogenic and chromogenic reaction applied in enzyme activity assay and immunoassay. Anal Chem 90(12):7754–7760 - DOI
    1. Yildirim A, Bayindir M (2014) Turn-on fluorescent dopamine sensing based on in situ formation of visible light emitting polydopamine nanoparticles. Anal Chem 86(11):5508–5512 - DOI
    1. Lan Y, Yuan F, Fereja TH, Wang C, Lou B, Li J, Xu G (2019) Chemiluminescence of lucigenin/riboflavin and its application for selective and sensitive dopamine detection. Anal Chem 91(3):2135–2139 - DOI
    1. Zhang L, Cheng Y, Lei J, Liu Y, Hao Q, Ju H (2013) Stepwise chemical reaction strategy for highly sensitive electrochemiluminescent detection of dopamine. Anal Chem 85(16):8001–8007 - DOI

Publication types

LinkOut - more resources