An integrated E-Tube cap for sample preparation, isothermal amplification and label-free electrochemical detection of DNA
- PMID: 33991846
- PMCID: PMC8572321
- DOI: 10.1016/j.bios.2021.113306
An integrated E-Tube cap for sample preparation, isothermal amplification and label-free electrochemical detection of DNA
Abstract
A simple, disposable, and integrated electronic-tube cap (E-tube cap) for DNA detection at the point-of-care was designed, fabricated, and tested. The E-tube cap contains a 3D printed electrode substrate for DNA extraction and label-free pH sensing detection. One Flinders Technology Associates (Whatman FTA) membrane was incorporated into the 3D printed electrode substrate for the isolation, concentration, and purification of DNA. The E-tube cap with captured DNA by the membrane was inserted directly into a reaction tube for loop-mediated isothermal amplification (LAMP). The isothermal amplification process was monitored in real-time by a 3D printed electrochemical electrode coated with pH-sensitive material (carbon/iridium oxide layer). The pH sensing electrode showed an excellent linear response within the pH range of 6-9 with a slope of -31.32 ± 0.5 mV/pH at room temperature. The utility of the integrated E-tube cap was demonstrated by detecting the presence of lambda DNA spiked in saliva samples with a sensitivity of 100 copies per mL sample within 30 min. Such a simple, rapid, and affordable diagnostic device is particularly suitable for point-of-care molecular diagnostics of infectious diseases.
Keywords: 3D-printing; Electrochemical detection; Isothermal amplification (LAMP); Loop-mediated; Point-of-care molecular diagnostics; pH-sensitive electrode.
Copyright © 2021 Elsevier B.V. All rights reserved.
Conflict of interest statement
Declaration of interests
The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
Figures
References
-
- Castellon J, Nguyen HN, Agnel S, Toureille A, Frechette M, Savoie S, Krivda A, Schmidt LE, 2011. IEEE Trans. Dielectr. Electr. Insul 18(3), 651–658.
-
- De Marco R, Pejcic B, 2000. Anal. Chem 72(4), 669–679. - PubMed
-
- Estrada-Peña A, Roura X, Sainz A, Miró G, Solano-Gallego L, 2017. Ticks Tick. Borne. Dis 8(4), 443–452. - PubMed
-
- Fu L, Tang D, Zhuang J, Lai W, Que X, Chen G, 2013. Biosens. Bioelectron 47, 106–112. - PubMed
-
- Ges IA, Ivanov BL, Werdich AA, Baudenbacher FJ, 2007. Biosens. Bioelectron 22(7), 1303–1310. - PubMed
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous