Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2021 Jun;9(6):439-449.
doi: 10.1016/j.jchf.2021.02.013. Epub 2021 May 12.

The Addition of a Defibrillator to Resynchronization Therapy Decreases Mortality in Patients With Nonischemic Cardiomyopathy

Affiliations
Free article
Randomized Controlled Trial

The Addition of a Defibrillator to Resynchronization Therapy Decreases Mortality in Patients With Nonischemic Cardiomyopathy

Bethany Doran et al. JACC Heart Fail. 2021 Jun.
Free article

Abstract

Objectives: The aim of this study was to determine whether patients with heart failure with reduced ejection fraction (HFrEF) due to nonischemic etiology eligible for cardiac resynchronization therapy (CRT) benefit from an implantable cardioverter-defibrillator (ICD).

Background: It is uncertain whether CRT with an ICD (CRT-D) compared to without an ICD (CRT-P) is associated with a survival benefit in patients with nonischemic etiologies of HFrEF.

Methods: Analyses of the COMPANION (Comparison of Medical Therapy, Pacing, and Defibrillation in Heart Failure) trial were performed, using Cox proportional hazards modeling stratified by HFrEF etiology of nonischemic cardiomyopathy (NICM) or ischemic cardiomyopathy (ICM). The primary outcome was all-cause mortality (ACM), and secondary outcomes were the combination of cardiovascular mortality or heart failure hospitalization and sudden cardiac death.

Results: Among patients randomized to CRT (n = 1,212), 236 (19.5%) died, 131 and 105 in the CRT-P and CRT-D arms, respectively. The unadjusted and adjusted hazard ratios (HRs) for CRT-D versus CRT-P were both 0.84 (95% confidence interval [CI]: 0.65 to 1.09) for ACM, with a significant device-etiology interaction (pinteraction = 0.015 adjusted; pinteraction = 0.040 unadjusted). In patients with NICM (n = 555), CRT-D versus CRT-P was associated with reduced ACM (adjusted HR: 0.54; 95% CI: 0.34 to 0.86), while patients with ICM (n = 657) did not exhibit a between-device reduction in ACM (adjusted HR: 1.05; 95% CI: 0.77 to 1.44). The effects of CRT-D versus CRT-P on sudden cardiac death (advantage CRT-D) and cardiovascular mortality or heart failure hospitalization (no difference between CRT-P and CRT-D) were similar between the 2 HFrEF etiologies.

Conclusions: COMPANION patients with NICM exhibited a decrease in ACM associated with CRT-D but not CRT-P treatment, whereas patients with ICM did not.

Keywords: cardiac resynchronization therapy; heart failure with reduced ejection fraction; implantable cardioverter-defibrillator; nonischemic cardiomyopathy.

PubMed Disclaimer

Conflict of interest statement

Funding Support and Author Disclosures This analysis was supported by the Statistical Data Analysis Center at the University of Wisconsin, by the University of Colorado Division of Cardiology, and by an American Heart Association Strategically Focused Network Grant in Heart Failure awarded to Drs. Bristow and Buttrick. The corporate sponsor of the COMPANION trial, Boston Scientific, provided no funding to the study. Drs. Feldman, Saxon, and Bristow were consultants for Guidant Corporation during the planning and execution of the COMPANION trial. Drs. Doran and Bristow are supported by an American Heart Association Strategically Focused Network Grant in Heart Failure. Dr. DeMets is a founder of the Statistical Data Analysis Center at the University of Wisconsin, where he is an emeritus professor. The Statistical and Data Analysis Center provided biostatistical support for the analyses performed by Mr. Mei in the current study. All other authors have reported that they have no relationships relevant to the contents of this paper to disclose.

Comment in

Similar articles

Cited by

Publication types

LinkOut - more resources