Doppler-derived cardiac output in healthy newborn infants in relation to physiological patency of the ductus arteriosus
- PMID: 3399430
- DOI: 10.1007/BF02083704
Doppler-derived cardiac output in healthy newborn infants in relation to physiological patency of the ductus arteriosus
Abstract
Noninvasive Doppler-derived cardiac output was measured with the pulsed Doppler method in 22 healthy newborns during their first four days of life. Maximal blood flow velocity in the aorta was measured with the Doppler ultrasound method. The mean Doppler-derived cardiac output was 273 +/- 59 ml/min/kg. Ductal left-to-right shunting was also determined and then graded according to the flow in the main pulmonary artery. The mean Doppler-derived cardiac output was 301 +/- 61 ml/min/kg when there was a moderate ductal left-to-right shunt, 266 +/- 59 ml/min/kg when the shunting was mild, and 260 +/- 53 ml/min/kg when there was no shunting ductus. The Doppler-derived cardiac output was significantly higher when there was a moderate left-to-right shunt than without such shunting. This method seems to be a useful approach in monitoring the cardiac function of newborns without unduly disturbing their condition. Normal values on Doppler-derived cardiac output have to be judged in relation to the magnitude of ductal left-to-right shunt.
Similar articles
-
High Doppler-derived cardiac output in the cerebral arteriovenous fistula measured by pulsed Doppler ultrasound.Z Kinderchir. 1988 Feb;43(1):42-3. doi: 10.1055/s-2008-1043411. Z Kinderchir. 1988. PMID: 3376590
-
Noninvasive Doppler echocardiographic evaluation of shunt flow dynamics of the ductus arteriosus.Circulation. 1987 Jun;75(6):1146-53. doi: 10.1161/01.cir.75.6.1146. Circulation. 1987. PMID: 3568325
-
Pulsed Doppler measurement of left ventricular output as early predictor of symptomatic patent ductus arteriosus in very preterm infants.Biol Neonate. 1989;56(3):121-8. doi: 10.1159/000243112. Biol Neonate. 1989. PMID: 2804176
-
The patent ductus arteriosus in term infants, children, and adults.Semin Perinatol. 2012 Apr;36(2):146-53. doi: 10.1053/j.semperi.2011.09.025. Semin Perinatol. 2012. PMID: 22414886 Review.
-
Role of echocardiography on the evaluation of patent ductus arteriosus in newborns.J Matern Fetal Neonatal Med. 2009;22 Suppl 3:10-3. doi: 10.1080/14767050903198181. J Matern Fetal Neonatal Med. 2009. PMID: 19757330 Review.
Cited by
-
Gut blood flow velocities in the newborn: effects of patent ductus arteriosus and parenteral indomethacin.Arch Dis Child. 1991 Jun;66(6):749. doi: 10.1136/adc.66.6.749-b. Arch Dis Child. 1991. PMID: 1796942 Free PMC article. No abstract available.
-
ULTRATHIN SILICON MEMBRANES FOR IMPROVING EXTRACORPOREAL BLOOD THERAPIES.Proc Int Conf Nanochannels Microchannels Minichannels. 2016;2016:V001T15A003. doi: 10.1115/ICNMM2016-8052. Epub 2016 Nov 9. Proc Int Conf Nanochannels Microchannels Minichannels. 2016. PMID: 31602425 Free PMC article.
-
Early determinants of right and left ventricular output in ventilated preterm infants.Arch Dis Child Fetal Neonatal Ed. 1996 Mar;74(2):F88-94. doi: 10.1136/fn.74.2.f88. Arch Dis Child Fetal Neonatal Ed. 1996. PMID: 8777673 Free PMC article.
-
Analysis of left ventricular regional wall motion in normal neonates.Br Heart J. 1992 Dec;68(6):574-9. doi: 10.1136/hrt.68.12.574. Br Heart J. 1992. PMID: 1467051 Free PMC article. Clinical Trial.
-
The methodology of Doppler-derived central blood flow measurements in newborn infants.Int J Pediatr. 2012;2012:680162. doi: 10.1155/2012/680162. Epub 2012 Jan 16. Int J Pediatr. 2012. PMID: 22291718 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources