Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Apr 12;13(4):e14436.
doi: 10.7759/cureus.14436.

Innovation in Permanent Pacemaker's Implantation Technique: Trans-Axillary Approach

Affiliations

Innovation in Permanent Pacemaker's Implantation Technique: Trans-Axillary Approach

Bakhtawar Shah et al. Cureus. .

Abstract

Introduction: Permanent pacemakers' (PPM) implantation is an integral part of electrophysiology and general cardiology. The implantation technique has evolved a lot since the first implantation. Several innovations have been undertaken to improve the effectiveness, life of the transplant, and patient outcomes. In this study, we introduced a new implantation technique to improve the procedure and possibly reduce the rate of complication.

Methods: This study was conducted from January 2016 to February 2017 in Hayatabad Medical Complex, Peshawar. Patients destined for implantation of PPM based on a clinical treatment plan, after proper explanation of the procedure, were brought to the catheterization laboratory. Venogram of the upper limb performed. Patients were scrubbed and draped. The axillary vein was approached via the Seldinger technique. About 2 to 3 cm superolateral to the puncture site, a skin incision was made and subcutaneous pocket constructed, and a guidewire external end was pulled in from inside the pocket keeping the venous end at the place. Subsequently, in a routine way, lead was placed, secured and the wound was closed in layers.

Results: A total of 690 PPM were implanted under the study. About 290 devices were implanted in the conventional way and 380 devices via the trans-axillary approach. The mean implantation time was less than 30 minutes via the trans-axillary approach. Immediate and delayed complications of the procedure were minimal.

Conclusion: Trans-axillary approach holds some significant advantages over the conventional technique. The subcutaneous pocket and venous puncture successfully reduce the burden of foreign material, minimize the tension on the wound, shorten implantation time and reduce the chances of erosion of the device.

Keywords: axillary vein; erosion; implantation; lead; permanent pacemakers; venogram.

PubMed Disclaimer

Conflict of interest statement

The authors have declared that no competing interests exist.

Similar articles

Cited by

References

    1. Acute coronary syndrome among older patients: a review. Veerasamy M, Edwards R, Ford G, Kirkwood T, Newton J, Jones D, Kunadian V. Cardiol Rev. 2015;23:26–32. - PubMed
    1. Coronary artery disease: new insights into the pathophysiology, prevalence, and early detection of a monster menace. Slater J, Rill V. Semin Ultrasound CT MR. 2004;24:114–122. - PubMed
    1. Evaluation of a simplified method of the conduction system analysis in 110 forensic cases. Michaud K, Romain N, Taroni F, et al. Forensic Sci Int. 2002;5:13–24. - PubMed
    1. Neonatal lupus: follow-up in infants with anti-SSA/Ro antibodies and review of the literature. Zuppa AA, Riccardi R, Frezza S, et al. Autoimmun Rev. 2017;16:427–432. - PubMed
    1. Congenital and childhood atrioventricular blocks: pathophysiology and contemporary management. Baruteau AE, Pass RH, Thambo JB, et al. Eur J Pediatr. 2016;175:1235–1248. - PMC - PubMed

LinkOut - more resources