Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2022 Jun;64(1):27-34.
doi: 10.1007/s10840-021-01002-1. Epub 2021 May 17.

One year outcome and analysis of peri-device leak of left atrial appendage occlusion devices

Affiliations
Randomized Controlled Trial

One year outcome and analysis of peri-device leak of left atrial appendage occlusion devices

Mohamad Jihad Mansour et al. J Interv Card Electrophysiol. 2022 Jun.

Abstract

Background: The prevalence of peri-device leak (PDL) of left atrial appendage occlusion (LAAO) devices has been previously reported. However, there have been only few data that compared different existing devices. The aim of this study was to assess the incidence of PDL with both devices WATCHMAN®, Boston Scientific and AMPLATZER Amulet®, Abbott Laboratories and to evaluate the clinical outcome at 12 months.

Methods: Consecutive patients who underwent LAAO between January 2018 and 2020 were randomly assigned to either WATCHMAN or AMPLATZER Amulet implantation based on a systematic 2-week alternation between both devices. LAA measurements were assessed using cardiac computed tomography angiography (CCTA) prior to and transesophageal echocardiography (TEE) during the procedure. At 8 weeks post-LAAO, patients underwent TEE and/or CCTA to identify the presence of PDL and/or device-related complications. Patients were then followed for 12 months to identify major adverse cardiovascular/embolic events.

Results: The cohort consisted of 51 patients (25 WATCHMAN, 26 AMPLATZER Amulet; mean age 76 ± 7 years; male gender 76%). Both groups were identically matched for demographics, comorbidities, and indication for LAAO. There were 19 patients who had PDL (13 WATCHMAN vs. 6 AMPLATZER Amulet, P-value = 0.033). Of them, 8 (15%) patients had significant PDL (7 WATCHMAN vs. 1 AMPLATZER Amulet, P-value = 0.018). On CCTA, the landing zone maximal diameter of the AMPLATZER Amulet device had the strongest correlation with the final deployed device size (Spearman's rho 0.92, P-value < 0.0001). In the multivariate analysis, male gender and device type were independent predictors of any PDL (P-values 0.016 and 0.031, respectively). On a mean follow-up of 12 months, the total number of events was more prevalent in the WATCHMAN group (P-value 0.008), but the incidence of cardio-embolic events reached borderline significance (16% vs. 0%, P-value = 0.051).

Conclusions: Among patients who underwent LAAO, almost 15% had significant PDL with the majority belonging to the WATCHMAN group. Still, larger studies are warranted to evaluate its effectiveness in stroke prevention.

Keywords: AMPLATZER Amulet; Atrial fibrillation; Cardiac computed tomography angiography; Echocardiography; Left atrial appendage occlusion; Stroke; WATCHMAN.

PubMed Disclaimer

References

    1. Fountain RB, Holmes DR, Chandrasekaran K, Packer D, Asirvatham S, Van Tassel R, Turi Z. The PROTECT AF (WATCHMAN Left Atrial Appendage System for Embolic PROTECTion in Patients with Atrial Fibrillation) trial. Am Heart J. 2006;151:956–61. - DOI
    1. Holmes DR, Reddy VY, Turi ZG, Doshi SK, Sievert H, Buchbinder M, PROTECT‐AF Investigators, et al. Percutaneous closure of the left atrial appendage versus warfarin therapy for prevention of stroke in patients with atrial fibrillation: a randomised non-inferiority trial. Lancet. 2009;374:534–42. - DOI
    1. Holmes DR, Kar S, Price MJ, Whisenant B, Sievert H, Doshi SK, et al. Prospective randomized evaluation of the Watchman Left Atrial Appendage Closure device in patients with atrial fibrillation versus long-term warfarin therapy: the PREVAIL trial. J Am Coll Cardiol. 2014;64(1):1–12. - DOI
    1. Ostermayer SH, Reisman M, Kramer PH, et al. Percutaneous left atrial appendage transcatheter occlusion (PLAATO system) to prevent stroke in high-risk patients with non-rheumatic atrial fibrillation: results from the international multicenter feasibility trials. J Am Coll Cardiol. 2005;46:9–14. - DOI
    1. Fastner C, Hoffmann L, Aboukoura M, Behnes M, Lang S, Borggrefe M, et al. Real-world experience comparing two common left atrial appendage closure devices. BMC Cardiovasc Disord. 2018;18:171. - DOI

Publication types

MeSH terms

LinkOut - more resources