Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2021 Oct;54(10):1769-1781.
doi: 10.1111/iej.13569. Epub 2021 Jun 22.

Influence of metal artefact reduction tool on the detection of vertical root fractures involving teeth with intracanal materials in cone beam computed tomography images: A systematic review and meta-analysis

Affiliations
Meta-Analysis

Influence of metal artefact reduction tool on the detection of vertical root fractures involving teeth with intracanal materials in cone beam computed tomography images: A systematic review and meta-analysis

Rocharles C Fontenele et al. Int Endod J. 2021 Oct.

Abstract

Background: The effectiveness of the metal artefact reduction (MAR) tool for the detection of vertical root fracture (VRF) by cone beam computed tomography (CBCT) images is controversial.

Objective: To evaluate the effectiveness of the MAR tool on VRF detection involving teeth with intracanal materials in CBCT images.

Methodology: In September 2019, an electronic search was performed in six databases (PubMed, Scopus, Web of Science, Cochrane, Lilacs and Embase). The electronic search was updated in May 2020 through searches in Google Scholar and references of included studies (embracing the electronic and gray literature searches). No language or year restrictions were applied. Independently, two reviewers examined titles, abstracts and full texts according to the eligibility criteria that were as follows: diagnostic studies that evaluated the effectiveness of the MAR tool on the diagnosis of VRF in human teeth (laboratory or in vivo studies) on CBCT images. The risk of bias was evaluated using the Quality Assessment Tool for Diagnostic of Accuracy Studies-2 (QUADAS-2). For conducting the meta-analysis, the values of sensitivity, specificity, diagnostic odds ratio (DOR) and area under the ROC curve (AUC) were obtained, considering the subgroups with and without MAR active. The Grading of Recommendation, Assessment, Development and Evaluation instrument was applied to assess the level of evidence across the studies using GRADEpro software.

Results: A total of 8 laboratory studies were included in both systematic review and meta-analysis. The values of sensitivity, specificity, DOR and AUC to VRF diagnosis with and without MAR active were, respectively, 0.586 and 0.603; 0.699 and 0.713, 3.037 and 3.767; 0.67 and 0.71. The quality of the evidence suggested low confidence in estimating the outcomes.

Discussion: The MAR tool decreased slightly the diagnostic values of VRF involving teeth with intracanal materials in laboratory studies. However, it is important to highlight that most studies had an uncertain risk of bias.

Conclusions: Although a low level of evidence and high heterogeneity were observed in the included studies, the meta-analysis revealed better diagnosis values for VRF detection when the MAR was deactivated when analysing extracted teeth in a laboratory setting.

Registration: PROSPERO-CRD42020145222.

Funding: This study was financed in party by the Coordenação de Aperfeiçoamento de Pessoal de Nível Superior-Brasil (CAPES).

Keywords: artefact; cone beam computed tomography; meta-analysis; systematic review; tooth fractures.

PubMed Disclaimer

Similar articles

Cited by

References

REFERENCES

    1. AAE and AAOMR Joint Position Statement. (2015) Use of cone beam computed tomography in endodontis. Journal of Endodontics, 41, 1392-1396.
    1. Bankier, A.A., Levine, D., Halpern, E.F. & Kressel, H.Y. (2010) Consensus interpretation in imaging research: is there a better way? Radiology, 257, 14-17.
    1. Bechara, B., Alex McMahan, C., Moore, W.S., Noujeim, M., Teixeira, F.B. & Geha, H. (2013a) Cone beam CT scans with and without artefact reduction in root fracture detection of endodontically treated teeth. Dentomaxillofacial Radiology, 42, 20120245.
    1. Bechara, B., McMahan, C.A., Noujeim, M., Faddoul, T., Moore, W.S., Teixeira, F.B. et al. (2013b) Comparison of cone beam CT scans with enhanced photostimulated phosphor plate images in the detection of root fracture of endodontically treated teeth. Dentomaxillofacial Radiology, 42, 20120404.
    1. Bezerra, I.S.Q., Neves, F.S., Vasconcelos, T.V., Ambrosano, G.M.B. & Freitas, D.Q. (2015) Influence of the artefact algorithm pf Picasso Trio CBCT system on the diagnosis of vertical root fractures in teeth with metal posts. Dentomaxillofacial Radiology, 44, 20140428.

LinkOut - more resources