Influence of metal artefact reduction tool on the detection of vertical root fractures involving teeth with intracanal materials in cone beam computed tomography images: A systematic review and meta-analysis
- PMID: 34003491
- DOI: 10.1111/iej.13569
Influence of metal artefact reduction tool on the detection of vertical root fractures involving teeth with intracanal materials in cone beam computed tomography images: A systematic review and meta-analysis
Abstract
Background: The effectiveness of the metal artefact reduction (MAR) tool for the detection of vertical root fracture (VRF) by cone beam computed tomography (CBCT) images is controversial.
Objective: To evaluate the effectiveness of the MAR tool on VRF detection involving teeth with intracanal materials in CBCT images.
Methodology: In September 2019, an electronic search was performed in six databases (PubMed, Scopus, Web of Science, Cochrane, Lilacs and Embase). The electronic search was updated in May 2020 through searches in Google Scholar and references of included studies (embracing the electronic and gray literature searches). No language or year restrictions were applied. Independently, two reviewers examined titles, abstracts and full texts according to the eligibility criteria that were as follows: diagnostic studies that evaluated the effectiveness of the MAR tool on the diagnosis of VRF in human teeth (laboratory or in vivo studies) on CBCT images. The risk of bias was evaluated using the Quality Assessment Tool for Diagnostic of Accuracy Studies-2 (QUADAS-2). For conducting the meta-analysis, the values of sensitivity, specificity, diagnostic odds ratio (DOR) and area under the ROC curve (AUC) were obtained, considering the subgroups with and without MAR active. The Grading of Recommendation, Assessment, Development and Evaluation instrument was applied to assess the level of evidence across the studies using GRADEpro software.
Results: A total of 8 laboratory studies were included in both systematic review and meta-analysis. The values of sensitivity, specificity, DOR and AUC to VRF diagnosis with and without MAR active were, respectively, 0.586 and 0.603; 0.699 and 0.713, 3.037 and 3.767; 0.67 and 0.71. The quality of the evidence suggested low confidence in estimating the outcomes.
Discussion: The MAR tool decreased slightly the diagnostic values of VRF involving teeth with intracanal materials in laboratory studies. However, it is important to highlight that most studies had an uncertain risk of bias.
Conclusions: Although a low level of evidence and high heterogeneity were observed in the included studies, the meta-analysis revealed better diagnosis values for VRF detection when the MAR was deactivated when analysing extracted teeth in a laboratory setting.
Registration: PROSPERO-CRD42020145222.
Funding: This study was financed in party by the Coordenação de Aperfeiçoamento de Pessoal de Nível Superior-Brasil (CAPES).
Keywords: artefact; cone beam computed tomography; meta-analysis; systematic review; tooth fractures.
© 2021 International Endodontic Journal. Published by John Wiley & Sons Ltd.
Similar articles
-
Diagnosis of Vertical Root Fractures by Cone-beam Computed Tomography in Root-filled Teeth with Confirmation by Direct Visualization: A Systematic Review and Meta-Analysis.J Endod. 2021 Aug;47(8):1198-1214. doi: 10.1016/j.joen.2021.04.022. Epub 2021 May 11. J Endod. 2021. PMID: 33984375
-
Influence of the technical parameters of CBCT image acquisition on vertical root fracture diagnosis: a systematic review and meta-analysis.Clin Oral Investig. 2023 Feb;27(2):433-474. doi: 10.1007/s00784-022-04797-z. Epub 2023 Jan 26. Clin Oral Investig. 2023. PMID: 36700991
-
Role of Cone-beam Computed Tomography in Diagnosis of Vertical Root Fractures: A Systematic Review and Meta-analysis.J Endod. 2016 Jan;42(1):12-24. doi: 10.1016/j.joen.2015.09.012. J Endod. 2016. PMID: 26699923
-
Cone-beam Computed Tomography for Detecting Vertical Root Fractures in Endodontically Treated Teeth: A Systematic Review.J Endod. 2016 Feb;42(2):177-85. doi: 10.1016/j.joen.2015.10.005. Epub 2015 Nov 26. J Endod. 2016. PMID: 26631300
-
Signs and symptoms to determine if a patient presenting in primary care or hospital outpatient settings has COVID-19.Cochrane Database Syst Rev. 2022 May 20;5(5):CD013665. doi: 10.1002/14651858.CD013665.pub3. Cochrane Database Syst Rev. 2022. PMID: 35593186 Free PMC article.
Cited by
-
Present status and future directions: vertical root fractures in root filled teeth.Int Endod J. 2022 May;55 Suppl 3(Suppl 3):804-826. doi: 10.1111/iej.13737. Epub 2022 Apr 15. Int Endod J. 2022. PMID: 35338655 Free PMC article. Review.
-
Influence of artefacts generated by titanium and zirconium implants in the study of trabecular bone architecture in cone-beam CT images.Dentomaxillofac Radiol. 2022 Sep 1;51(6):20220066. doi: 10.1259/dmfr.20220066. Epub 2022 May 4. Dentomaxillofac Radiol. 2022. PMID: 35466693 Free PMC article.
-
Combining different metal artifact reduction levels with sharpening filters and slice thickness for the visualization of mandibular canals perforated by implants.Clin Oral Investig. 2024 Nov 7;28(12):632. doi: 10.1007/s00784-024-06031-4. Clin Oral Investig. 2024. PMID: 39505740
-
Endodontic Orthograde Retreatments: Challenges and Solutions.Clin Cosmet Investig Dent. 2023 Oct 24;15:245-265. doi: 10.2147/CCIDE.S397835. eCollection 2023. Clin Cosmet Investig Dent. 2023. PMID: 37899987 Free PMC article. Review.
-
Effect of metal artefact reduction level on the assessment of dental implant positioning by cone-beam computed tomography.Dentomaxillofac Radiol. 2024 Apr 29;53(4):233-239. doi: 10.1093/dmfr/twae008. Dentomaxillofac Radiol. 2024. PMID: 38466923 Free PMC article.
References
REFERENCES
-
- AAE and AAOMR Joint Position Statement. (2015) Use of cone beam computed tomography in endodontis. Journal of Endodontics, 41, 1392-1396.
-
- Bankier, A.A., Levine, D., Halpern, E.F. & Kressel, H.Y. (2010) Consensus interpretation in imaging research: is there a better way? Radiology, 257, 14-17.
-
- Bechara, B., Alex McMahan, C., Moore, W.S., Noujeim, M., Teixeira, F.B. & Geha, H. (2013a) Cone beam CT scans with and without artefact reduction in root fracture detection of endodontically treated teeth. Dentomaxillofacial Radiology, 42, 20120245.
-
- Bechara, B., McMahan, C.A., Noujeim, M., Faddoul, T., Moore, W.S., Teixeira, F.B. et al. (2013b) Comparison of cone beam CT scans with enhanced photostimulated phosphor plate images in the detection of root fracture of endodontically treated teeth. Dentomaxillofacial Radiology, 42, 20120404.
-
- Bezerra, I.S.Q., Neves, F.S., Vasconcelos, T.V., Ambrosano, G.M.B. & Freitas, D.Q. (2015) Influence of the artefact algorithm pf Picasso Trio CBCT system on the diagnosis of vertical root fractures in teeth with metal posts. Dentomaxillofacial Radiology, 44, 20140428.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources