Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Jun;16(6):2968-2990.
doi: 10.1038/s41596-021-00528-y. Epub 2021 May 19.

Fabricating and printing chemiresistors based on monolayer-capped metal nanoparticles

Affiliations

Fabricating and printing chemiresistors based on monolayer-capped metal nanoparticles

Yana Milyutin et al. Nat Protoc. 2021 Jun.

Abstract

Chemiresistors that are based on monolayer-capped metal nanoparticles (MCNPs) have been used in a wide variety of innovative sensing applications, including detection and monitoring of diagnostic markers in body fluids, explosive materials, environmental contaminations and food quality control. The sensing mechanism is based on reversible swelling or aggregation and/or changes in dielectric constant of the MCNPs. In this protocol, we describe a procedure for producing MCNP-based chemiresistive sensors that is reproducible from device to device and from batch to batch. The approach relies on three main steps: (i) controlled synthesis of gold MCNPs, (ii) fabrication of electrodes that are surrounded with a microbarrier ring to confine the deposited MCNP solution and (iii) a tailor-made drying process to enable evaporation of solvent residues from the MCNP sensing layer to prevent a coffee-ring effect. Application of this approach has been shown to produce devices with ±1.5% variance-a value consistent with the criterion for commercial sensors-as well as long shelf life and stability. Fabrication of chemical sensors based on dodecanethiol- or 2-ethylhexanethiol-capped MCNPs with this approach provides high sensitivity and accuracy in the detection of volatile organic compounds (e.g., octane and decane), toxic gaseous species (e.g., HCl and NH3) in air and simulated mixtures of lung and gastric cancer from exhaled breath.

PubMed Disclaimer

References

    1. Nakhleh, M. K. et al. Diagnosis and classification of 17 diseases from 1404 subjects via pattern analysis of exhaled molecules. ACS Nano 11, 112–125 (2017). - PubMed - DOI
    1. Shlomi, D. et al. Detection of lung cancer and EGFR mutation by electronic nose system. J. Thorac. Oncol. 12, 1544–1551 (2017). - PubMed - DOI
    1. Feinberg, T. et al. Cancer metabolism: the volatile signature of glycolysis—in vitro model in lung cancer cells. J. Breath. Res. 11, 016008 (2017). - PubMed - DOI
    1. Amal, H. et al. Breath testing as potential colorectal cancer screening tool. Int J. Cancer 138, 229–236 (2016). - PubMed - DOI
    1. Kahn, N., Lavie, O., Paz, M., Segev, Y. & Haick, H. Dynamic nanoparticle-based flexible sensors: diagnosis of ovarian carcinoma from exhaled breath. Nano Lett. 15, 7023–7028 (2015). - PubMed - DOI

Publication types

LinkOut - more resources