Side effects in excimer corneal surgery. Corneal thermal gradients
- PMID: 3402751
- DOI: 10.1007/BF02181196
Side effects in excimer corneal surgery. Corneal thermal gradients
Abstract
Thermal loading is a significant side effect during excimer laser surgery of the cornea. The maximal temperature rise, which is dependent on fluence and repetition rate of the radiation, amounts to 20 degrees C in excised corneas and 7.5 degrees C in the in situ cornea. The temperature decreases exponentially with increasing distance from the incision with a half-value distance of 610 +/- 100 micron. Exposure parameters are recommended to avoid temperature rises greater than 11 degrees C.
Similar articles
-
High-speed recording of thermal load during laser trans-epithelial corneal refractive surgery using a 750Hz ablation system.J Optom. 2019 Apr-Jun;12(2):84-91. doi: 10.1016/j.optom.2018.05.002. Epub 2018 Jul 20. J Optom. 2019. PMID: 30037645 Free PMC article.
-
Thermal side effects of fiber-guided XeCl excimer laser drilling of cartilage.Lasers Surg Med. 1994;14(3):278-86. doi: 10.1002/lsm.1900140310. Lasers Surg Med. 1994. PMID: 8208054
-
Evaluation of an opacity lensometer for determining corneal clarity following excimer laser photoablation.Refract Corneal Surg. 1990 Sep-Oct;6(5):346-51. Refract Corneal Surg. 1990. PMID: 2257259
-
Excimer laser corneal surgery: new strategies and old enemies.Invest Ophthalmol Vis Sci. 1995 Jan;36(1):4-8. Invest Ophthalmol Vis Sci. 1995. PMID: 7822157 Review. No abstract available.
-
[A review of mathematical descriptors of corneal asphericity].J Fr Ophtalmol. 2002 Jan;25(1):81-90. J Fr Ophtalmol. 2002. PMID: 11965125 Review. French.
Cited by
-
High-speed recording of thermal load during laser trans-epithelial corneal refractive surgery using a 750Hz ablation system.J Optom. 2019 Apr-Jun;12(2):84-91. doi: 10.1016/j.optom.2018.05.002. Epub 2018 Jul 20. J Optom. 2019. PMID: 30037645 Free PMC article.
-
Development of a system for excimer laser corneal surgery.Trans Am Ophthalmol Soc. 1989;87:854-983. Trans Am Ophthalmol Soc. 1989. PMID: 2562535 Free PMC article. No abstract available.
-
Effect of thermal preconditioning before excimer laser photoablation.J Korean Med Sci. 2004 Jun;19(3):437-46. doi: 10.3346/jkms.2004.19.3.437. J Korean Med Sci. 2004. PMID: 15201513 Free PMC article.
-
Side effects in excimer corneal surgery. DNA damage as a result of 193 nm excimer laser radiation.Graefes Arch Clin Exp Ophthalmol. 1988;226(3):273-6. doi: 10.1007/BF02181195. Graefes Arch Clin Exp Ophthalmol. 1988. PMID: 3402750
-
The SCHWIND AMARIS Total-Tech Laser as An All-Rounder in Refractive Surgery.Middle East Afr J Ophthalmol. 2009 Jan;16(1):46-53. doi: 10.4103/0974-9233.48868. Middle East Afr J Ophthalmol. 2009. PMID: 20142960 Free PMC article.
References
MeSH terms
Substances
LinkOut - more resources
Other Literature Sources