Bipolar hemiarthroplasty for fracture of the femoral neck. Clinical review with special emphasis on prosthetic motion
- PMID: 3403568
Bipolar hemiarthroplasty for fracture of the femoral neck. Clinical review with special emphasis on prosthetic motion
Abstract
The results of a consecutive series of 120 bipolar replacements of the femoral head that had been done for the treatment of a fracture of the femoral neck were reviewed. Ninety patients were followed for a minimum of two years. At the latest follow-up, eighty-two (91 per cent) of the patients were free of major pain, and eighty-three (92 per cent) were considered to have satisfactory motion and muscle power. Postoperative function often was limited by underlying medical problems. Seventy-five patients (83 per cent) either returned to the level of function that they had had before the fracture or used only a cane, which they had not needed previously. There was no important deterioration of the results with time. For twenty-six of the prostheses, roentgenograms were made with the patient bearing weight in order to determine the relative motion at the two sites of articulation of the bipolar prosthesis. The roentgenograms demonstrated the presence and maintenance of motion at both bearing surfaces.
Similar articles
-
Fractures of the femoral neck treated with a bipolar endoprosthesis.Clin Orthop Relat Res. 1987 May;(218):63-7. Clin Orthop Relat Res. 1987. PMID: 3568497
-
[Observation of prosthesis movement after implantation of the bipolar artificial femoral head].Zhonghua Wai Ke Za Zhi. 1992 Oct;30(10):581-4, 635. Zhonghua Wai Ke Za Zhi. 1992. PMID: 1306787 Chinese.
-
Joint motion of bipolar femoral prostheses.J Arthroplasty. 1995 Apr;10(2):237-43. doi: 10.1016/s0883-5403(05)80133-0. J Arthroplasty. 1995. PMID: 7798107
-
Fractures of the femoral neck: a review and personal statement.Acta Chir Orthop Traumatol Cech. 2006;73(1):45-59. Acta Chir Orthop Traumatol Cech. 2006. PMID: 16613748 Review.
-
[Bipolar endoprosthesis in fractures of the femoral neck. Apropos of 201 cases, 116 after a 6-year follow-up].Rev Chir Orthop Reparatrice Appar Mot. 1992;78(3):191-200. Rev Chir Orthop Reparatrice Appar Mot. 1992. PMID: 1439032 Review. French.
Cited by
-
The Exeter bipolar prosthesis in the active elderly patient: the results at 7 years.Int Orthop. 1992;16(4):344-8. doi: 10.1007/BF00189617. Int Orthop. 1992. PMID: 1473887
-
The BHU bicentric bipolar prosthesis in fracture neck femur in active elderly.J Trauma Manag Outcomes. 2008 Sep 25;2(1):7. doi: 10.1186/1752-2897-2-7. J Trauma Manag Outcomes. 2008. PMID: 18817566 Free PMC article.
-
The challenge of geriatric hip fractures.Bull N Y Acad Med. 1990 May-Jun;66(3):255-65. Bull N Y Acad Med. 1990. PMID: 2364218 Free PMC article. No abstract available.
-
Higher cartilage wear in unipolar than bipolar hemiarthroplasties of the hip at 2 years: A randomized controlled radiostereometric study in 19 fit elderly patients with femoral neck fractures.Acta Orthop. 2018 Oct;89(5):503-508. doi: 10.1080/17453674.2018.1475899. Epub 2018 May 23. Acta Orthop. 2018. PMID: 29790397 Free PMC article. Clinical Trial.
-
The cartilage degeneration and joint motion of bipolar hemiarthroplasty.Int Orthop. 2012 Oct;36(10):2015-20. doi: 10.1007/s00264-012-1567-9. Epub 2012 May 17. Int Orthop. 2012. PMID: 22588693 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical