Experiences with use of a pulse oximeter multimodal device in outpatient management of children with Acute Respiratory Infection during Covid pandemic
- PMID: 34041052
- PMCID: PMC8138404
- DOI: 10.4103/jfmpc.jfmpc_1410_20
Experiences with use of a pulse oximeter multimodal device in outpatient management of children with Acute Respiratory Infection during Covid pandemic
Abstract
Background: While Covid-19 infection rate in children is low, respiratory symptoms are a common mode of presentation which calls for better management of such symptoms. However, ARI case managemnet in primary health settings settings has challenges as health workers lack skills to count respiratory rate and check chest indrawing. To address this multimodal pulse oximeters have been introduced in health and wellness centres of seven states to ease the work of front line health workers. A study was undertaken to understand the usability of the multimodal pulse oximeter during Covid times.
Methods: A qualitative study was conducted with the aid of indepth interviews among a convenience sample of eleven health care workers from ten health and wellness centres. Interviews were conducted and recorded over phone, after obtaining consent. Transcribed interviews were coded and analysed on a qualitative analysis software. Content analysis was conducted.
Results: Total children screened during covid lockdown period (April 1-May 31) is 571, those diagnosed with pneumonia and severe pneumonia is 68 and 2. Health care workers were satisfied with pulse oximeter as it helped in timely diagnosis and treatment, and offered protection from possible infection as it mitigated the need for physical contact.
Conclusion: The multimodal pulse oximeter is well accepted among providers as it is easy to use aiding in timely management of ARI in children. It has an added protection as it's use reduces the need for physical contact. It can be adopted in other HWC and primary health facilities.
Keywords: Childhood pneumonia; Covid 19; Health and Wellness Centre; infection prevention; pulse oximeter.
Copyright: © 2021 Journal of Family Medicine and Primary Care.
Conflict of interest statement
There are no conflicts of interest.
Similar articles
-
Experiences From an Implementation Model of ARI Diagnostic Device in Pneumonia Case Management Among Under-5 Children in Peripheral Healthcare Centers in India.Clin Med Insights Pediatr. 2021 Nov 15;15:11795565211056649. doi: 10.1177/11795565211056649. eCollection 2021. Clin Med Insights Pediatr. 2021. PMID: 34803419 Free PMC article.
-
Childhood pneumonia diagnostics: community health workers' and national stakeholders' differing perspectives of new and existing aids.Glob Health Action. 2017;10(1):1290340. doi: 10.1080/16549716.2017.1290340. Glob Health Action. 2017. PMID: 28485694 Free PMC article.
-
Automated Respiratory Rate Counter to Assess Children for Symptoms of Pneumonia: Protocol for Cross-Sectional Usability and Acceptability Studies in Ethiopia and Nepal.JMIR Res Protoc. 2020 Mar 30;9(3):e14405. doi: 10.2196/14405. JMIR Res Protoc. 2020. PMID: 32224491 Free PMC article.
-
Performance of five pulse oximeters to detect hypoxaemia as an indicator of severe illness in children under five by frontline health workers in low resource settings - A prospective, multicentre, single-blinded, trial in Cambodia, Ethiopia, South Sudan, and Uganda.EClinicalMedicine. 2021 Jul 22;38:101040. doi: 10.1016/j.eclinm.2021.101040. eCollection 2021 Aug. EClinicalMedicine. 2021. PMID: 34368660 Free PMC article.
-
Outpatient Management of Children With World Health Organization Chest Indrawing Pneumonia: Implementation Risks and Proposed Solutions.Clin Infect Dis. 2017 Oct 16;65(9):1560-1564. doi: 10.1093/cid/cix543. Clin Infect Dis. 2017. PMID: 29020216 Free PMC article. Review.
Cited by
-
An innovative method to prevent infection when measuring the arterial blood gas SpO2 saturation.GMS Hyg Infect Control. 2024 Apr 17;19:Doc18. doi: 10.3205/dgkh000473. eCollection 2024. GMS Hyg Infect Control. 2024. PMID: 38766637 Free PMC article.
-
Designing a Smartphone-Based Pulse Oximeter for Children in South Africa (Phefumla Project): Qualitative Analysis of Human-Centered Design Workshops With Health Care Workers.JMIR Hum Factors. 2024 May 30;11:e54983. doi: 10.2196/54983. JMIR Hum Factors. 2024. PMID: 38825834 Free PMC article.
-
Patient and clinician use characteristics and perceptions of pulse oximeter use: A scoping review.Int J Med Inform. 2022 Jun;162:104735. doi: 10.1016/j.ijmedinf.2022.104735. Epub 2022 Mar 18. Int J Med Inform. 2022. PMID: 35325661 Free PMC article.
-
Effect of using disposable polyethylene bag as a probe cover or finger cover in pulse oximetry.J Family Med Prim Care. 2022 Feb;11(2):708-714. doi: 10.4103/jfmpc.jfmpc_1364_21. Epub 2022 Feb 16. J Family Med Prim Care. 2022. PMID: 35360786 Free PMC article.
-
Health System Considerations for Community-Based Implementation of Automated Respiratory Counters to Identify Childhood Pneumonia in 5 Regions of Ethiopia: A Qualitative Study.Int J Health Policy Manag. 2023;12:7385. doi: 10.34172/ijhpm.2023.7385. Epub 2023 Oct 18. Int J Health Policy Manag. 2023. PMID: 38618793 Free PMC article.
References
-
- Shekerdemian LS, Mahmood NR, Wolfe KK, Riggs BJ, Ross CE, McKiernan CA, et al. Characteristics and outcomes of children with coronavirus disease 2019 (COVID-19) infection admitted to US and Canadian Pediatric Intensive Care Units. JAMA Pediatr. 2020 doi: 10.1001/jamapediatrics. 2020.AQ8 1948. - PMC - PubMed
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous