Caution warranted in use of indocyanine green fluorescence in laparoscopic evaluation of microcirculation in acute small bowel obstruction
- PMID: 34042255
- DOI: 10.1111/codi.15757
Caution warranted in use of indocyanine green fluorescence in laparoscopic evaluation of microcirculation in acute small bowel obstruction
Comment on
-
The use of indocyanine green fluorescence to define bowel microcirculation during laparoscopic surgery for acute small bowel obstruction.Colorectal Dis. 2021 Aug;23(8):2189-2194. doi: 10.1111/codi.15680. Epub 2021 May 5. Colorectal Dis. 2021. PMID: 33876537
References
REFERENCE
-
- Guerra F, Colette D, Greco PA, Eugene E, Partita A. The use of indocyanine green fluorescence to define bowel microcirculation during laparoscopic surgery for acute small bowel obstruction. Colorectal Dis. 2021:1-6. https://doi.org/10.1111/codi.15680