. 2021 Aug;36(8):2722-2728.
doi: 10.1111/jocs.15662. Epub 2021 May 28.

Validity of echocardiography for detection of left ventricular thrombus with surgical validation in patients awaiting durable left ventricular assist device

Affiliations

Validity of echocardiography for detection of left ventricular thrombus with surgical validation in patients awaiting durable left ventricular assist device

David J Bae et al. J Card Surg. 2021 Aug.

Abstract

Objective: Unrecognized left ventricular thrombi (LVT) can have devastating clinical implications and precludes patients with end-stage heart failure from undergoing left ventricular assist device (LVAD) implantation without cardiopulmonary bypass assistance. We assessed the reliability of an echocardiogram to diagnose LVT in patients with end-stage heart disease who underwent LVAD implantation.

Methods: A single-center retrospective study evaluated 232 consecutive adult patients requiring implantation of durable LVADs between 2005 and 2019. The validity of preoperative transthoracic echocardiogram (TTE) and intraoperative transesophageal echocardiogram (TEE) for diagnosing LVT was compared to direct inspection at the time of LVAD implantation.

Results: There were 232 patients that underwent LVAD implantation, with 226 patients (97%) receiving a preoperative TTE. Of those 226 patients, 32 patients (14%) received ultrasound enhancing agents (UEA). Intraoperative TEE images were available in 195 patients (84%). The sensitivity of TTE without UEA was 22% and specificity was 90% for detecting LVT, compared to 50% and 86%, respectively, for TTE with UEA. For intraoperative TEE, the sensitivity and specificity were 46% and 96%, respectively. The false omission rate ranged from 4% to 8% for all modalities of echocardiography.

Conclusion: Among patients undergoing LVAD implantation, preoperative TTE and intraoperative TEE had poor sensitivity for LVT detection. Up to 8% of echocardiograms were incorrectly concluded to be negative for LVT on surgical validation. The low sensitivity and positive predictive value for diagnosing LVT suggest that echocardiography has limited reliability in this cohort of patients who are at high risk of LVT formation and its subsequent complications.

Keywords: echocardiography; left ventricular assist device; left ventricular thrombus; off-pump.

PubMed Disclaimer

References

REFERENCES

    1. Bettari L , Fiuzat M , Becker R , Felker GM , Metra M , O'Connor CM . Thromboembolism and antithrombotic therapy in patients with heart failure in sinus rhythm. Circulation: Heart Failure. 2011;4:361-368.
    1. Loh E , Sutton MS , Wun CC , et al. Ventricular dysfunction and the risk of stroke after myocardial infarction. N Engl J Med. 1997;336:251-257.
    1. Stock UA , Kornberger A , Reyher C , et al. Minimally-Invasive Access and Off-Pump LVAD Implantation - Strategies to Improve Outcomes. J Heart Lung Transplant. 2016;35:S328.
    1. Strueber M , Meyer AL , Feussner M , Ender J , Correia JC , Mohr FW . A minimally invasive off-pump implantation technique for continuous-flow left ventricular assist devices: early experience. J Heart Lung Transplant. 2014;33:851-856.
    1. Lang RM , Badano LP , Mor-Avi V , et al. Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. European Heart Journal-Cardiovascular Imaging. 2015;16:233-271.

LinkOut - more resources