[Evaluation of the tolerance of the intra-ocular injection of hydroxypropyl methylcellulose in animal experiments]
- PMID: 3404946
- DOI: 10.1055/s-2008-1050122
[Evaluation of the tolerance of the intra-ocular injection of hydroxypropyl methylcellulose in animal experiments]
Abstract
Hydroxy-propyl-methyl-cellulose (HPMC) was injected into the anterior chambers or vitreous bodies of rabbit eyes in order to test local and systemic tolerance. In doing so the typical intraoperative complication of capsule rupture, which, in anterior segment surgery in man, allows HPMC to enter the vitreous body, was simulated. Neither clinically, nor in laboratory workup, nor histopathologically could any difference be shown between the local and systemic reactions of HPMC and those of DRSS. The data obtained in the study admit the conclusion that HPMC can be used in surgery of the anterior segment without any risk of adverse reactions.
Similar articles
-
[Biocompatibility and pharmacokinetics of hydroxypropyl methylcellulose (HPMC) in the anterior chamber of the rabbit eye].Klin Monbl Augenheilkd. 1990 Jun;196(6):470-4. doi: 10.1055/s-2008-1046226. Klin Monbl Augenheilkd. 1990. PMID: 2376944 German.
-
[Experimental data on methicillin tolerance and penetration into the eye media].Antibiotiki. 1975 Apr;20(4):311-5. Antibiotiki. 1975. PMID: 1211896 Russian.
-
Comparison of vitreous replacement with Healon and with HPMC in rabbits' eyes.Doc Ophthalmol. 1986 Jan 15;61(3-4):247-53. doi: 10.1007/BF00142350. Doc Ophthalmol. 1986. PMID: 3948660
-
Visualizing the vitreous body in the anterior chamber using 11-deoxycortisol after posterior capsule rupture in an animal model.Ophthalmology. 2004 Jul;111(7):1334-9. doi: 10.1016/j.ophtha.2003.11.011. Ophthalmology. 2004. PMID: 15234133
-
Safety assessment of hydroxypropyl methylcellulose as a food ingredient.Food Chem Toxicol. 2007 Dec;45(12):2341-51. doi: 10.1016/j.fct.2007.07.011. Epub 2007 Jul 26. Food Chem Toxicol. 2007. PMID: 17723258 Review.
Cited by
-
[Artificial vitreous body: Strategies for vitreous body substitutes].Ophthalmologe. 2015 Jul;112(7):572-9. doi: 10.1007/s00347-015-0057-z. Ophthalmologe. 2015. PMID: 26077344 Review. German.
-
Vitreous substitutes: the present and the future.Biomed Res Int. 2014;2014:351804. doi: 10.1155/2014/351804. Epub 2014 May 4. Biomed Res Int. 2014. PMID: 24877085 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical