Microcirculatory hematocrit and blood flow
- PMID: 3405001
- DOI: 10.1016/s0022-5193(88)80238-8
Microcirculatory hematocrit and blood flow
Abstract
Direct measurements from many laboratories indicate that the oxygen tension in skeletal muscle is significantly less than in the large veins draining these tissues. Harris (1986) has proposed that because of the parallel anatomic arrangement of large arterioles and venules in skeletal muscle, a counter-current exchange between these vessels can occur. He theorized that diffusion of O2 between arteriole and venule would lower the PO2 in the blood as it enters capillaries and result in a decreased tissue PO2 and an increase in large vein PO2. Calculations (Appendix) show that the amount of O2 transferred between arteriole and venule is inadequate to account for this difference in PO2 between tissue and veins due to the small surface area that is involved. It is well documented that the microcirculatory hematocrit ranges between 20 and 50% of that in the supply vessels. The reduced hematocrit lowers the oxygen content in these vessels and results in a low oxygen tension in the surrounding tissue. True arteriovenous shunts are not present in most skeletal muscles, but 15-20% of the microvessels represent thoroughfare or preferential flow channels. It is suggested that these vessels contain a greater than normal hematocrit to account for a conservation of red cell mass across the microcirculation. Furthermore, it is shown that the hematocrit in the preferential flow channels is an inverse function of the flow rate for any level of the microcirculatory hematocrit. The increased hematocrit raises the flow resistance in these vessels which reduces flow further and represents a positive feedback condition which may contribute to the intermittent and uneven flow patterns which are present within the microcirculation.(ABSTRACT TRUNCATED AT 250 WORDS)
Similar articles
-
Effect of hemodilution on oxygen transport in arteriolar networks of hamster striated muscle.Am J Physiol. 1988 Feb;254(2 Pt 2):H331-9. doi: 10.1152/ajpheart.1988.254.2.H331. Am J Physiol. 1988. PMID: 3344823
-
Arteriovenous oxygen diffusion shunt is negligible in resting and working gracilis muscles.Am J Physiol. 1991 Dec;261(6 Pt 2):H2031-43. doi: 10.1152/ajpheart.1991.261.6.H2031. Am J Physiol. 1991. PMID: 1750549
-
Model analysis of the enhancement of tissue oxygenation by hemodilution due to increased microvascular flow velocity.Microvasc Res. 1987 Nov;34(3):290-301. doi: 10.1016/0026-2862(87)90062-8. Microvasc Res. 1987. PMID: 3431480
-
An examination of the measurement of flow heterogeneity in striated muscle.Circ Res. 1987 Jan;60(1):1-13. doi: 10.1161/01.res.60.1.1. Circ Res. 1987. PMID: 3552283 Review.
-
Oxygen supply to contracting skeletal muscle at the microcirculatory level: diffusion vs. convection.Acta Physiol Scand. 2000 Apr;168(4):593-602. doi: 10.1046/j.1365-201x.2000.00710.x. Acta Physiol Scand. 2000. PMID: 10759595 Review.
Cited by
-
The flow of anisotropic nanoparticles in solution and in blood.Exploration (Beijing). 2023 Oct 10;3(6):20220075. doi: 10.1002/EXP.20220075. eCollection 2023 Dec. Exploration (Beijing). 2023. PMID: 38264690 Free PMC article. Review.
-
Engineering Synthetic Erythrocytes as Next-Generation Blood Substitutes.Adv Funct Mater. 2024 Jul 10;34(28):2315879. doi: 10.1002/adfm.202315879. Epub 2024 Feb 8. Adv Funct Mater. 2024. PMID: 39386164 Free PMC article.
-
A parallel fluid-solid coupling model using LAMMPS and Palabos based on the immersed boundary method.J Comput Sci. 2018 Mar;25:89-100. doi: 10.1016/j.jocs.2018.02.006. Epub 2018 Feb 14. J Comput Sci. 2018. PMID: 30220942 Free PMC article.
-
Low intensity shear stress increases endothelial ELR+ CXC chemokine production via a focal adhesion kinase-p38{beta} MAPK-NF-{kappa}B pathway.J Biol Chem. 2009 Feb 27;284(9):5945-55. doi: 10.1074/jbc.M807205200. Epub 2008 Dec 31. J Biol Chem. 2009. PMID: 19117939 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources