Computer-Aided Design and Manufacturing versus Conventional Surgical Planning for Head and Neck Reconstruction: A Systematic Review and Meta-Analysis
- PMID: 34076623
- DOI: 10.1097/PRS.0000000000008085
Computer-Aided Design and Manufacturing versus Conventional Surgical Planning for Head and Neck Reconstruction: A Systematic Review and Meta-Analysis
Abstract
Background: Virtual surgical planning and computer-aided design/computer-aided manufacturing (CAD/CAM) for complex head and neck reconstruction has a number of cited advantages over conventional surgical planning, such as increased operative efficiency, fewer complications, improved osseous flap union, immediate osseointegrated dental implant placement, and superior functional and aesthetic outcomes. The authors performed a systematic review and meta-analysis of the available evidence on CAD/CAM maxillofacial reconstruction with the primary purpose of determining which approach is more efficacious.
Methods: In accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, a PubMed and Embase database search was performed to identify English-language, human-subject studies of CAD/CAM-assisted head and neck reconstruction. All comparative studies were included in a meta-analysis to identify differences in operative time, ischemia time, surgical-site occurrence, microvascular complication, and partial or total flap loss between the two groups. All included studies (comparative and noncomparative) were used in the systematic review, summarizing the various flap characteristics, technical nuances, and functional and aesthetic outcomes.
Results: Twelve articles were included in the meta-analysis, representing 277 patients in the CAD/CAM group and 419 patients in the conventional group. CAD/CAM was associated with 65.3 fewer minutes of operating room time (95 percent CI, -72.7 to -57.9 minutes; p < 0.0001) and 34.8 fewer minutes of ischemia time (95 percent CI, -38 to -31.5 minutes; p < 0.0001). There were no significant differences in surgical-site occurrence, nonunion, flap loss, microvascular complications, or hardware-related complications.
Conclusions: CAD/CAM is associated with shorter operating room and ischemia times. There are no significant differences in flap or hardware-related complications between CAD/CAM and conventional surgical planning.
Copyright © 2021 by the American Society of Plastic Surgeons.
Similar articles
-
Computer-Aided Design and Manufacturing in Free Fibula Reconstruction of the Mandible: Comparison of Long-Term Outcomes.Plast Reconstr Surg. 2025 May 1;155(5):910e-920e. doi: 10.1097/PRS.0000000000011701. Epub 2024 Oct 18. Plast Reconstr Surg. 2025. PMID: 39436738
-
Aesthetic reconstruction of onco-surgical maxillary defects using free scapular flap with and without CAD/CAM customized osteotomy guide.BMC Surg. 2022 Oct 19;22(1):362. doi: 10.1186/s12893-022-01811-9. BMC Surg. 2022. PMID: 36261822 Free PMC article. Clinical Trial.
-
Virtual surgical planning in fibula free flap head and neck reconstruction: A systematic review and meta-analysis.J Plast Reconstr Aesthet Surg. 2019 Sep;72(9):1465-1477. doi: 10.1016/j.bjps.2019.06.013. Epub 2019 Jul 2. J Plast Reconstr Aesthet Surg. 2019. PMID: 31324403
-
Computer-assisted versus conventional free fibula flap technique for craniofacial reconstruction: an outcomes comparison.Plast Reconstr Surg. 2013 Nov;132(5):1219-1228. doi: 10.1097/PRS.0b013e3182a3c0b1. Plast Reconstr Surg. 2013. PMID: 23924648
-
The Complications of Osseous Reconstruction in the Head and Neck: A Systematic Review and Meta-analysis.Otolaryngol Head Neck Surg. 2024 Sep;171(3):631-641. doi: 10.1002/ohn.793. Epub 2024 Jun 17. Otolaryngol Head Neck Surg. 2024. PMID: 38881407
Cited by
-
Precise maxillofacial soft tissue reconstruction: A combination of cone beam computed tomography and 3dMD photogrammetry system.Heliyon. 2024 Jun 7;10(12):e32513. doi: 10.1016/j.heliyon.2024.e32513. eCollection 2024 Jun 30. Heliyon. 2024. PMID: 38994088 Free PMC article.
-
Bone reconstruction using CAD/CAM technology in head and neck surgical oncology. A narrative review of state of the art and aesthetic-functional outcomes.Acta Otorhinolaryngol Ital. 2024 May;44(Suppl. 1):S58-S66. doi: 10.14639/0392-100X-suppl.1-44-2024-N2819. Acta Otorhinolaryngol Ital. 2024. PMID: 38745517 Free PMC article. Review.
-
Computer-Assisted Surgery in Mandible Reconstruction.Semin Plast Surg. 2024 May 27;38(3):198-208. doi: 10.1055/s-0044-1786805. eCollection 2024 Aug. Semin Plast Surg. 2024. PMID: 39118858 Free PMC article. Review.
-
Progress of Ossification after Mandibular Reconstruction by Free Fibula Flap Depending on Different Timing of Radiotherapy: A Retrospective 3D Analysis by CT Scans.J Clin Med. 2024 Jul 13;13(14):4104. doi: 10.3390/jcm13144104. J Clin Med. 2024. PMID: 39064143 Free PMC article.
-
Innovative Strategies in Microvascular Head and Neck Reconstruction.Medicina (Kaunas). 2023 Jun 24;59(7):1194. doi: 10.3390/medicina59071194. Medicina (Kaunas). 2023. PMID: 37512006 Free PMC article. Review.
References
-
- Largo RD, Garvey PB. Updates in head and neck reconstruction. Plast Reconstr Surg. 2018;141:271e–285e.
-
- Kamali P, Dean D, Skoracki R, et al. The current role of three-dimensional printing in plastic surgery. Plast Reconstr Surg. 2016;137:1045–1055.
-
- Weitz J, Bauer FJ, Hapfelmeier A, Rohleder NH, Wolff KD, Kesting MR. Accuracy of mandibular reconstruction by three-dimensional guided vascularised fibular free flap after segmental mandibulectomy. Br J Oral Maxillofac Surg. 2016;54:506–510.
-
- Hanasono MM, Skoracki RJ. Computer-assisted design and rapid prototype modeling in microvascular mandible reconstruction. Laryngoscope. 2013;123:597–604.
-
- Kokosis G, Davidson EH, Pedreira R, Macmillan A, Dorafshar AH. The use of computer-aided design and manufacturing in acute mandibular trauma reconstruction. J Oral Maxillofac Surg. 2018;76:1036–1043.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous