Intraoperative testing of the integrity of left-sided colorectal anastomoses: a technique of value to the surgeon in training
- PMID: 3408174
- PMCID: PMC2498752
Intraoperative testing of the integrity of left-sided colorectal anastomoses: a technique of value to the surgeon in training
Abstract
Left-sided colorectal anastomoses sometimes leak despite the best efforts of the surgeon. The cause is thought to be multifactorial but imperfections in the technique of performing the anastomosis must play some part. A method for testing the integrity of left-sided colorectal anastomoses has been developed using intraluminal distension. Twenty-one patients were studied and defects in the anastomosis were found in five (24%). These defects were rectified at the time of operation. We conclude that this method is useful for demonstrating imperfections in anastomotic technique and we suggest a distending pressure of 25 cm saline. We suggest that the method may be particularly useful for the surgeon in training.
Comment in
-
Intraoperative testing of the integrity of left-sided colorectal anastomoses: a technique of value to the surgeon in training.Ann R Coll Surg Engl. 1990 Jan;72(1):66. Ann R Coll Surg Engl. 1990. PMID: 1688325 Free PMC article. No abstract available.
-
Intraoperative testing of the integrity of left-sided colorectal anastomoses: a technique of value to the surgeon in training.Ann R Coll Surg Engl. 1989 Sep;71(5):338. Ann R Coll Surg Engl. 1989. PMID: 2802485 Free PMC article. No abstract available.
Similar articles
-
Intraoperative testing of the integrity of left-sided colorectal anastomoses: a technique of value to the surgeon in training.Ann R Coll Surg Engl. 1988 Nov;70(6):397. Ann R Coll Surg Engl. 1988. PMID: 3207337 Free PMC article. No abstract available.
-
Intraoperative testing of the integrity of left-sided colorectal anastomoses: a technique of value to the surgeon in training.Ann R Coll Surg Engl. 1988 Sep;70(5):338. Ann R Coll Surg Engl. 1988. PMID: 3190137 Free PMC article. No abstract available.
-
Intraoperative testing of the integrity of left-sided colorectal anastomoses: a technique of value to the surgeon in training.Ann R Coll Surg Engl. 1989 Sep;71(5):338. Ann R Coll Surg Engl. 1989. PMID: 2802485 Free PMC article. No abstract available.
-
Stapled anastomoses in colorectal surgery: a prospective study.Eur J Surg. 1996 Oct;162(10):805-10. Eur J Surg. 1996. PMID: 8934111 Review.
-
[Mechanical versus manual anastomoses in colorectal surgery. Personal experience].G Chir. 2008 Nov-Dec;29(11-12):505-10. G Chir. 2008. PMID: 19068189 Review. Italian.
Cited by
-
Saline volume required to achieve peristaltic intraluminal pressure during leak testing of canine colotomies, using two methods of luminal occlusion.Open Vet J. 2024 May;14(5):1130-1134. doi: 10.5455/OVJ.2024.v14.i5.6. Epub 2024 May 31. Open Vet J. 2024. PMID: 38938420 Free PMC article.
-
Experimental Study of Mechanical Integrity Testing in Stapled Large Bowel: Methylene Blue Leak Test Is Not Inferior to Air Leak Test.Visc Med. 2021 Jun;37(3):189-197. doi: 10.1159/000510660. Epub 2020 Oct 12. Visc Med. 2021. PMID: 34250076 Free PMC article.
-
Intraoperative evaluation of colorectal anastomotic integrity: a comparison of air leak and dye leak tests.Tech Coloproctol. 2021 Jul;25(7):841-847. doi: 10.1007/s10151-021-02453-4. Epub 2021 Apr 27. Tech Coloproctol. 2021. PMID: 33905010
-
Intraoperative assessment of colorectal anastomotic integrity: a systematic review.Surg Endosc. 2014 Sep;28(9):2513-30. doi: 10.1007/s00464-014-3520-z. Epub 2014 Apr 10. Surg Endosc. 2014. PMID: 24718665
-
Assessment of the use of disposable skin staplers in bowel anastomoses to reduce laparotomy time in penetrating ballistic injury to the abdomen.Ann R Coll Surg Engl. 1991 Mar;73(2):87-90. Ann R Coll Surg Engl. 1991. PMID: 2018326 Free PMC article.
References
MeSH terms
LinkOut - more resources
Full Text Sources
Medical