Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Oct;49(5):999-1006.
doi: 10.1007/s15010-021-01634-5. Epub 2021 Jun 5.

The emergence of Staphylococcus aureus as the primary cause of cardiac device-related infective endocarditis

Affiliations

The emergence of Staphylococcus aureus as the primary cause of cardiac device-related infective endocarditis

Jean-Marie Urien et al. Infection. 2021 Oct.

Abstract

Background: Increasing use of cardiovascular implantable electronic devices (CIED), as permanent pacemakers (PPM), implantable cardioverter defibrillators (ICD), or cardiac resynchronization therapy (CRT), is associated with the emergence of CIED-related infective endocarditis (CIED-IE). We aimed to characterize CIED-IE profile, temporal trends, and prognostic factors.

Methods: CIED-IE diagnosed at Rennes University Hospital during years 1992-2017 were identified through computerized database, and included if they presented all of the following: (1) clinical signs of infection; (2) microbiological documentation through blood and/or CIED lead cultures; (3) lead or valve vegetation, or definite IE according to Duke criteria. Data were retrospectively extracted from medical charts. The cohort was categorized in three periods: 1992-1999, 2000-2008, and 2009-2017.

Results: We included 199 patients (51 women, 148 men, median age 73 years [interquartile range, 64-79]), with CIED-IE: 158 PPMs (79%), 24 ICD (12%), and 17 CRT (9%). Main pathogens were coagulase-negative staphylococci (CoNS: n = 86, 43%), Staphylococcus aureus (n = 60, 30%), and other Gram-positive cocci (n = 28, 14%). Temporal trends were remarkable for the decline in CoNS (P = 0.002), and the emergence of S. aureus as the primary cause of CIED-IE (24/63 in 2009-2017, 38%). Factors independently associated with one-year mortality were chronic obstructive pulmonary disease (COPD: hazard ratio 3.84 [1.03-6.02], P = 0.03), left-sided endocarditis (HR 2.25 [1.09-4.65], P = 0.03), pathogens other than CoNS (HR 3.16 [1.19-8.39], P = 0.02), and CIED removal/reimplantation (HR 0.41 [0.20-0.83], P = 0.01).

Conclusions: S. aureus has emerged as the primary cause of CIED-IE. Left-sided endocarditis, COPD, pathogens other than CoNS, and no CIED removal/reimplantation are independent risk factors for one-year mortality.

Keywords: Cardiac device; Coagulase negative staphylococci; Endocarditis; Staphylococcus aureus.

PubMed Disclaimer

References

    1. Sandoe JA, Barlow G, Chambers JB, Gammage M, Guleri A, Howard P, et al. Guidelines for the diagnosis, prevention and management of implantable cardiac electronic device infection. Report of a joint Working Party project on behalf of the British Society for Antimicrobial Chemotherapy (BSAC, host organization), British Heart Rhythm Society (BHRS), British Cardiovascular Society (BCS), British Heart Valve Society (BHVS) and British Society for Echocardiography (BSE). J Antimicrob Chemother. 2015;70(2):325–59. - DOI
    1. Kusumoto FM, Schoenfeld MH, Wilkoff BL, Berul CI, Birgersdotter-Green UM, Carrillo R, et al. 2017 HRS expert consensus statement on cardiovascular implantable electronic device lead management and extraction. Heart Rhythm. 2017;14:e503–51. - DOI
    1. Loffler S, Kasper J, Postulka J, Cornak V, Bohunicky F, Zelenay J, et al. Septic complications in patients with permanent pacemakers. Cor Vasa. 1988;30:400–4. - PubMed
    1. Baddour LM, Epstein AE, Erickson CC, Knight BP, Levison ME, Lockhart PB, et al. Update on cardiovascular implantable electronic device infections and their management: a scientific statement from the American Heart Association. Circulation. 2010;121:458–77. - DOI
    1. Cabell CH, Heidenreich PA, Chu VH, Moore CM, Stryjewski ME, Corey GR, et al. Increasing rates of cardiac device infections among Medicare beneficiaries: 1990–1999. Am Heart J. 2004;147:582–6. - DOI

LinkOut - more resources