Sensitivity analysis of a multibranched light guide for real time hyperspectral imaging systems
- PMID: 34092891
 - PMCID: PMC8176559
 - DOI: 10.1117/12.2510506
 
Sensitivity analysis of a multibranched light guide for real time hyperspectral imaging systems
Abstract
Hyperspectral imaging (HSI) is a spectroscopic technique which captures images at a high contrast over a wide range of wavelengths to show pixel specific composition. Traditional uses of HSI include: satellite imagery, food distribution quality control and digital archaeological reconstruction. Our lab has focused on developing applications of HSI fluorescence imaging systems to study molecule-specific detection for rapid cell signaling events or real-time endoscopic screening. Previously, we have developed a prototype spectral light source, using our modified imaging technique, excitation-scanning hyperspectral imaging (HIFEX), coupled to a commercial colonoscope for feasibility testing. The 16 wavelength LED array was combined, using a multi-branched solid light guide, to couple to the scope's optical input. The prototype acquired a spectral scan at near video-rate speeds (∼8 fps). The prototype could operate at very rapid wavelength switch speeds, limited to the on/off rates of the LEDs (∼10 μs), but imaging speed was limited due to optical transmission losses (∼98%) through the solid light guide. Here we present a continuation of our previous work in performing an in-depth analysis of the solid light guide to optimize the optical intensity throughput. The parameters evaluated include: LED intensity input, geometry (branch curvature and combination) and light propagation using outer claddings. Simulations were conducted using a Monte Carlo ray tracing software (TracePro). Results show that transmission within the branched light guide may be optimized through LED focusing lenses, bend radii and smooth tangential branch merges. Future work will test a new fabricated light guide from the optimized model framework.
Keywords: Colonoscopy; Colorectal Cancer; Endoscopy; Light Emitting Diode; Spectroscopy.
Figures
              
              
              
              
                
                
                
              
              
              
              
                
                
                
              
              
              
              
                
                
                
              
              
              
              
                
                
                
              
              
              
              
                
                
                
              
              
              
              
                
                
                References
- 
    
- Siegel R, Desantis C, and Jemal A, "Colorectal cancer statistics, 2014.," CA: a cancer journal for clinicians 64(2), 104–117 (2014). - PubMed
 
 - 
    
- Siegel RL, Miller KD, and Jemal A, "Cancer statistics, 2016," CA: a cancer journal for clinicians 66(1), 7–30 (2016). - PubMed
 
 - 
    
- Siegel RL, Miller KD, and Jemal A, "Cancer statistics, 2017," CA: A Cancer Journal for Clinicians 67(1), 7–30 (2017). - PubMed
 
 - 
    
- Rex DK, Cutler CS, Lemmel GT, Rahmani EY, Clark DW, Helper DJ, Lehman GA, and Mark DG, "Colonoscopic miss rates of adenomas determined by back-to-back colonoscopies," Gastroenterology 112(1), 24–28 (1997). - PubMed
 
 - 
    
- van Rijn J, Reitsma J, Stoker J, Bossuyt P, van Deventer S, and Dekker E, "Polyp miss rate determined by tandem colonoscopy: a systematic review.," The American journal of gastroenterology 101(2), 343 (2006). - PubMed
 
 
Grants and funding
LinkOut - more resources
Full Text Sources
Miscellaneous