Relationship of the cornea and globe dimensions to the changes in adult human crystalline lens diameter, thickness and power with age
- PMID: 34097905
- PMCID: PMC8595523
- DOI: 10.1016/j.exer.2021.108653
Relationship of the cornea and globe dimensions to the changes in adult human crystalline lens diameter, thickness and power with age
Abstract
It is well known that human crystalline lens shape, dimensions and optical properties change throughout life and influence whole eye refraction. However, it is not clear if lens properties are associated with other ocular parameters. The purpose of the present study was to investigate the relationship of corneal and external globe dimensions with adult lens diameter (LD), lens thickness (LT) and lens power (LP) in order to determine if external factors influence lens properties. Postmortem human eyes (n = 66, age = 20-78 years) were obtained from the Ramayamma International Eye Bank, Hyderabad, India. Globe antero-posterior length (GAPL) and mean (average of horizontal and vertical) diameters of cornea (MCD) and globe (MGD) were measured using digital calipers. Eyes were dissected to produce ocular structures that contain the lens maintained in its accommodating framework, including intact zonules, ciliary body and sections of sclera. Specimens were mounted in a mechanical lens stretching system. LD, LT and LP were measured using high magnification retro-illumination photography, slit illumination photography and Scheiner principle-based optical system respectively in the unstretched (accommodated) state. Relationships between external globe and corneal dimensions and LD, LT or LP were assessed by multiple regression analysis. Age (0.012 ± 0.003 mm/year; p<0.001) and GAPL (0.185 ± 0.045 mm/mm; p<0.001) were significant (p<0.0001) predictors of LD. After adjusting for age-related increases, LD appears to be positively correlated with GAPL. Age (0.010 ± 0.004 mm/year; p = 0.009) and GAPL (-0.143 ± 0.060 mm/mm; p = 0.02) were significant (p = 0.001) predictors of LT. After adjusting for the age-related increase, LT appears to be negatively correlated with GAPL. Only age was a significant predictor of LP (-0.26 ± 0.04 D/year; p<0.001). The results suggest that, apart from aging, lens diameter and thickness are dependent on the anteroposterior length of the eye globe. Lens power is not influenced by globe dimensions.
Keywords: Cornea; Crystalline lens; Diameter; Globe; Length; Multiple regression; Power; Thickness.
Copyright © 2021 Elsevier Ltd. All rights reserved.
Conflict of interest statement
Figures



Similar articles
-
Biometry of the human cornea and globe: An evaluation by age, gender and population.Exp Eye Res. 2022 Mar;216:108932. doi: 10.1016/j.exer.2022.108932. Epub 2022 Jan 15. Exp Eye Res. 2022. PMID: 35041822
-
Anterior segment biometry during accommodation imaged with ultralong scan depth optical coherence tomography.Ophthalmology. 2012 Dec;119(12):2479-85. doi: 10.1016/j.ophtha.2012.06.041. Epub 2012 Aug 17. Ophthalmology. 2012. PMID: 22902211 Free PMC article.
-
Age-dependence of the optomechanical responses of ex vivo human lenses from India and the USA, and the force required to produce these in a lens stretcher: the similarity to in vivo disaccommodation.Vision Res. 2011 Jul 15;51(14):1667-78. doi: 10.1016/j.visres.2011.05.009. Epub 2011 May 24. Vision Res. 2011. PMID: 21658404 Free PMC article.
-
The role of the lens in refractive development of the eye: animal models of ametropia.Exp Eye Res. 2008 Jul;87(1):3-8. doi: 10.1016/j.exer.2008.03.001. Epub 2008 Mar 18. Exp Eye Res. 2008. PMID: 18405895 Review.
-
The optics of the eye-lens and lenticular senescence. A review.Doc Ophthalmol. 1995;89(4):321-35. doi: 10.1007/BF01203708. Doc Ophthalmol. 1995. PMID: 7493534 Review.
Cited by
-
The relationships between lens diameter and ocular biometric parameters: an ultrasound biomicroscopy-based study.Front Med (Lausanne). 2024 Jan 15;10:1306276. doi: 10.3389/fmed.2023.1306276. eCollection 2023. Front Med (Lausanne). 2024. PMID: 38288306 Free PMC article.
-
Lens parameters and myopic shift in nuclear cataract after vitrectomy.Graefes Arch Clin Exp Ophthalmol. 2025 May 29. doi: 10.1007/s00417-025-06857-y. Online ahead of print. Graefes Arch Clin Exp Ophthalmol. 2025. PMID: 40442510
-
Ocular Biometry Features and Their Relationship with Anterior and Posterior Segment Lengths among a Myopia Population in Northern China.J Clin Med. 2024 Feb 9;13(4):1001. doi: 10.3390/jcm13041001. J Clin Med. 2024. PMID: 38398313 Free PMC article.
References
-
- Augusteyn RC, Mohamed A, Nankivil D, Veerendranath P, Arrieta E, Taneja M, Manns F, Ho A, Parel JM, 2011. Age-dependence of the optomechanical responses of ex vivo human lenses from India and the USA, and the force required to produce these in a lens stretcher: the similarity to in vivo disaccommodation. Vision. Res. 51, 1667–1678. 10.1016/j.visres.2011.05.009. - DOI - PMC - PubMed
-
- Augusteyn RC, Rosen AM, Borja D, Ziebarth NM, Parel JM, 2006. Biometry of primate lenses during immersion in preservation media. Mol. Vis. 12, 740–747. - PubMed
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Medical
Research Materials