Clinical evaluation of in-office tooth whitening with violet LED (405 nm): A double-blind randomized controlled clinical trial
- PMID: 34116249
- DOI: 10.1016/j.pdpdt.2021.102385
Clinical evaluation of in-office tooth whitening with violet LED (405 nm): A double-blind randomized controlled clinical trial
Abstract
Background: Although there is little evidence showing the effectiveness of violet LED on in-office tooth whitening, there are some studies which have reported satisfactory results. This double-blind randomized controlled clinical trial aimed to evaluate the effect of a violet light emission diode (LED) (405 nm) system, used in-office, on tooth whitening, sensitivity, use of medication after whitening and quality of life.
Methods: Eight patients were randomized into 4 groups (n = 20): G1 - violet LED, G2 - 35% carbamide peroxide (CP) and violet LED, G3 only CP 35% and G4 35% hydrogen peroxide (HP). The color was measured using a spectrophotometer at the following times: baseline, 15 and 180days. The colorimetric changes were analyzed using measurements from the CieLab System ΔE (ΔL, Δa and Δb) and the WID (Whiteness Index for Dentistry) for the 4 groups. Tooth sensitivity was recorded via a visual analog scale (VAS). Additionally, the Psychosocial Impact of Dental. Aesthetics Questionnaire (PIDAQ) was used to evaluate quality of life.
Results: For the analysis of ΔL, G4 and G2 presented more brightness than G1 and G3 (p<0.05), implying that G2 is at least as good as G4 (p>0.05). For measure of Δa, G4 presented better results, standing out from the other groups. (p<0.05). For Δb, both G4 and G2 showed a greater tendency for blue color than groups G1 and G3 (p <0.05). When analyzing ∆E at the 180-day follow up, G4 produced the highest ∆E, while G3 showed the lowest ∆E. The other 2 whitening groups produced intermediate ∆E values. For ∆W, G1 and G3 significantly differed from G2 and G3. When analyzing the 180-day follow up, G2 produced the highest ∆W, while G3 showed the lowest ∆W. The other two whitening treatments produced intermediate ∆W values. As for sensitivity, only G4 patients showed dental sensitivity within 24 h of the bleaching, with pain ceasing after 48 h. For G4, 33% of the patients needed to take analgesics within the first 24 h after the first 3 whitening sessions. For PIDAQ, there was no overall decrease in score over time for any of the groups and there was no difference between them (p>0.05).
Conclusion: Our results showed that violet LED was not able to whiten teeth at the same intensity, when used alone, as it was when associated with 35% CP, contrary to our initial hypothesis. However, given that pain was not consistently reported in G2, one could suggest that treatment with LED + 35% CP is quite similar to that of 35% HP when used for tooth whitening, but with better pain outcomes. All treatments suggested an improvement in quality of life.Clinical Trial Registry: This trial is registered at ClinicalTrials.gov; the registration number is NCT03192852 https://clinicaltrials.gov/ct2/show/NCT03192852.
Keywords: Carbamide peroxide; Color change; Hydrogen peroxide; Tooth sensitivity; Tooth whitening; Violet LED.
Copyright © 2021. Published by Elsevier B.V.
Similar articles
-
Using violet light during in-office tooth bleaching to enhance the efficacy of carbamide peroxide without increasing bleaching sensitivity: a systematic review and meta-analysis.Lasers Med Sci. 2025 May 10;40(1):218. doi: 10.1007/s10103-025-04476-x. Lasers Med Sci. 2025. PMID: 40346438 Review.
-
Evaluation of in-office tooth whitening treatment with violet LED: protocol for a randomised controlled clinical trial.BMJ Open. 2018 Sep 4;8(9):e021414. doi: 10.1136/bmjopen-2017-021414. BMJ Open. 2018. PMID: 30181185 Free PMC article.
-
Effect of violet LED light on in-office bleaching protocols: a randomized controlled clinical trial.J Appl Oral Sci. 2020;28:e20190720. doi: 10.1590/1678-7757-2019-0720. Epub 2020 May 18. J Appl Oral Sci. 2020. PMID: 32428059 Free PMC article. Clinical Trial.
-
The influence of violet LED light on tooth bleaching protocols: In vitro study of bleaching effectiveness.Photodiagnosis Photodyn Ther. 2020 Dec;32:102052. doi: 10.1016/j.pdpdt.2020.102052. Epub 2020 Oct 12. Photodiagnosis Photodyn Ther. 2020. PMID: 33059108
-
Clinical decision-making in tooth bleaching based on current evidence: A narrative review.Dent Mater. 2025 May;41(5):536-552. doi: 10.1016/j.dental.2025.03.002. Epub 2025 Mar 13. Dent Mater. 2025. PMID: 40082147 Review.
Cited by
-
Using violet light during in-office tooth bleaching to enhance the efficacy of carbamide peroxide without increasing bleaching sensitivity: a systematic review and meta-analysis.Lasers Med Sci. 2025 May 10;40(1):218. doi: 10.1007/s10103-025-04476-x. Lasers Med Sci. 2025. PMID: 40346438 Review.
-
Time-dependent efficacy and safety of tooth bleaching with cold plasma and H2O2 gel.BMC Oral Health. 2022 Nov 24;22(1):535. doi: 10.1186/s12903-022-02601-8. BMC Oral Health. 2022. PMID: 36424627 Free PMC article.
-
Interdental Plaque Microbial Community Changes under In Vitro Violet LED Irradiation.Antibiotics (Basel). 2021 Nov 4;10(11):1348. doi: 10.3390/antibiotics10111348. Antibiotics (Basel). 2021. PMID: 34827286 Free PMC article.
-
Bleaching efficacy and tooth sensitivity using violet LED - single-blind randomized controlled trial.Lasers Med Sci. 2025 May 19;40(1):228. doi: 10.1007/s10103-025-04486-9. Lasers Med Sci. 2025. PMID: 40383865 Clinical Trial.
Publication types
MeSH terms
Substances
Associated data
LinkOut - more resources
Full Text Sources
Medical
Research Materials
Miscellaneous