Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2021 Jun;24(6):828-832.
doi: 10.4103/njcp.njcp_374_20.

Evaluation of the marginal microleakage of CAD-CAM compared with conventional interim crowns luted with different types of cement: An in-vitro study

Affiliations

Evaluation of the marginal microleakage of CAD-CAM compared with conventional interim crowns luted with different types of cement: An in-vitro study

A Robaian et al. Niger J Clin Pract. 2021 Jun.

Abstract

Background: Temporary stage in crowns and bridgework plays an important role in the success and failure of the final restorations. Lack of marginal seal of the temporary restorations can lead to further complications. Recently, digital dentistry has been improved in terms of marginal integrity.

Aims: The aim of this study was to evaluate and compare the marginal leakage between CAD/CAM and conventionally made Polymethyl methacrylate (PMMA) interim crowns cemented with different temporary luting cements.

Materials and methods: Sixty resin dies of a maxillary right first premolar were prepared according to the protocol of the tooth preparation for all-ceramic crown. Interim crowns were then fabricated and assigned to two main groups according to the fabrication technique (CAD/CAM technique and conventional technique). Furthermore, the samples were sub-grouped (n = 10) according to the type of the luting cements: Zinc oxide eugenol (RelyX temp E), Zinc oxide non-eugenol (RelyX temp NE), and Zinc polycarboxylate cement (pentron). The specimens were then subjected to thermocycling at 5°C and 55°CC for 30 sec and transfer time of 15 seconds for 1500 cycles. After that, the specimens were immersed in a 2% methylene blue solution for 24 hours. The cemented specimens were sectioned buccolingually and the amount of marginal leakage was evaluated under digital microscope at magnification 50x. The scores of dye penetration were recorded and analyzed using one-way ANOVA at P < 0.05 for all tests.

Results: For the fabrication technique, CAD/CAM-made interim crowns had significantly better performance in terms of lower microleakage in comparison to conventionally built interim crowns (P < 0.001). Overall, Zinc Oxide non-eugenol also showed significantly least microleakage as a luting cement then Zinc Oxide Eugenol and the most microleakage was found with Zinc Polycarboxylate regardless of the fabrication method.

Conclusion: Interim crowns fabricated by CAD-CAM system are better suited for temporization. Zinc-oxide non-eugenol cements showed the least amount of microleakage in both types of crown.

Keywords: CAD-CAM system; interim crowns; luting cement; marginal leakage.