"Trapped labelled spins"-related signal on arterial spin labelling in the assessment of flow-diverted aneurysms: preliminary experience
- PMID: 34128085
- DOI: 10.1007/s00234-021-02721-y
"Trapped labelled spins"-related signal on arterial spin labelling in the assessment of flow-diverted aneurysms: preliminary experience
Abstract
Purpose: To investigate ASL-MRI features of flow-diverted aneurysms, review their haemodynamic surrogates, and discuss their pertinent clinical implications.
Methods: Retrospective single institutional analysis was performed on the clinical and imaging data of patients who underwent digital subtraction angiography (DSA) and ASL-MRI after endovascular flow diversion for cerebral aneurysms. Pseudo-continuous ASL-MRI was performed with post-label delays of 1525-1800 ms. Intra-aneurysmal "trapped labelled spins" (TLS)-related hypersignal, as seen on cerebral blood flow (CBF)-weighted maps of ASL-MRI, was investigated. Intermodality equivalence with DSA [O'Kelly-Marotta (OKM) grading for occlusion], 3D-TOF-MRA, and 3D spin-echo T1-weighted ("black-blood") images was assessed.
Results: Ten cases were included. "TLS" signal was demonstrable in 7/8 (87.5%) of the DSA-visible flow-diverted aneurysms (OKM grade B3, n = 6; OKM grade A3, n = 2). No TLS was seen in both OKM-D (excluded) aneurysms. TLS was not visualised in an OKM-B3 aneurysm with < 3 mm opacifying remnant. 3D-TOF-MRA and ASL-MRI were discordant at 5 instances (45.4%; TOF-MRA false negative, n = 4; false positive, n = 1). Loss of flow void on black-blood images corresponded to the absence of TLS and vice versa in all cases but one.
Conclusion: "Trapped labelled spins"-related signal on ASL-MRI occurs in patent large aneurysms that have undergone successful endovascular flow diversion. This phenomenon likely represents an interplay of a multitude of haemodynamic factors including decelerated intra-aneurysmal inflow and outflow restriction. Serial intra-saccular TLS signal changes may hold diagnostic value, including contexts where 3D-TOF-MRA interpretation becomes dubious. "Trapped labelled spins"-related signal as a non-invasive proxy marker of aneurysm patency can possibly obviate unnecessary DSA.
Keywords: Arterial spin labelling; Arterial transit artefact; Flow diversion; Flow diverter; Post-labelling delay; Trapped labelled spins.
© 2021. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.
References
-
- Brinjikji W, Murad MH, Lanzino G, Cloft HJ, Kallmes DF (2013) Endovascular treatment of intracranial aneurysms with flow diverters: a meta-analysis. Stroke 44:442–447 - DOI
-
- Walcott BP, Stapleton CJ, Choudhri O, Patel AB (2016) Flow diversion for the treatment of intracranial aneurysms. JAMA Neurol 73:1002 - DOI
-
- Briganti F, Leone G, Marseglia M, Mariniello G, Caranci F, Brunetti A, Maiuri F (2015) Endovascular treatment of cerebral aneurysms using flow-diverter devices: a systematic review. Neuroradiol J 28:365–375 - DOI
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical